Research Article

T-Shaped Control Plate Effect on Flow past a Square Cylinder at Low Reynolds Numbers

Table 6

Comparison of present results of flow past a square cylinder with available results.

Re = 100CDmeanStCDrmsCLrms

Present1.41250.14500.00350.1780
Dash et al. [6] (num)1.4600.14400.1840
Luo et al. [26] (exp)0.142–0.145
Okajima [27] (exp)0.140
Norberg [28] (exp)0.140
Sohankar et al. [29] (num)1.4440.14500.00190.130
Saha et al. [30] (num)0.00300.122
Re = 150CDmeanStCDrmsCLrms
Present1.40120.15200.01720.2732
Okajima [27] (exp)0.1420
Norberg [28] (exp)0.1550
Sohankar et al. [29] (num)1.40800.16100.00610.1770
Saha et al. [30] (num)0.01700.2740
Re = 200CDmeanStCDrmsCLrms
Present1.42680.15100.02940.3250
Okajima [27] (exp)0.1440
Norberg [28] (exp)0.1520
Sohankar et al. [29] (num)1.4240.1650.01210.240
Saha et al. [30] (num)0.02600.305
Dutta et al. [31] (exp)1.4100.154
Re = 250CDmeanStCDrmsCLrms
Present1.44320.14820.03480.4050
Sohankar et al. [29] (num)1.44900.15100.01620.375
Saha et al. [30] (num)0.03200.150