Research Article

Machine Learning-Based Fault Diagnosis of Self-Aligning Bearings for Rotating Machinery Using Infrared Thermography

Table 1

Specifications of the FLIR E60 thermal camera.

ParameterDescription

IR resolution (array size)76,800 (320 × 240)
Thermal sensitivity<0.05°C (50 mK)
Field of view25° × 19 °; optional lenses available
Temperature range−20 to 650°C (−4 to 1202°F)
Accuracy±2%
Image frequency60 Hz
FocusManual
Display screen3.5″ landscape touchscreen (widescreen)
Visual camera3.1 MP
Digital zoom4X continuous
Image fusion/picture-in-pictureYes/scalable