Research Article

Parameter Estimation of Solar PV Using Ali Baba and Forty Thieves Optimization Technique

Table 8

Comparison of actual and experimental values for the STP6-120/36 module.

S.noImIeIAE (current)VPePmIAE (power)RE

17.487.4722870.00771300000.001031
27.457.45019.97 × 10−059.0667.497967.4970.000903−1.30 × 10−05
37.427.4468630.0268639.4770.521870.26740.254396−0.00362
47.447.4366590.00334110.3276.7463276.78080.0344780.000449
57.417.4181510.00815111.1782.8607482.76970.091043−0.0011
67.387.3942430.01424311.8187.3260287.15780.168216−0.00193
77.377.3622550.00774512.3690.9974791.09320.095730.001051
87.347.3310170.00898312.7493.3971693.51160.1144410.001224
97.297.2843670.00563313.1695.8622695.93640.0741360.000773
107.237.2187980.01120213.5998.1034698.25570.1522380.001549
117.17.0902710.00972914.17100.4691100.6070.1378570.00137
126.976.9612430.00875714.58101.4949101.62260.1276810.001256
136.836.8180330.01196714.93101.7932101.97190.1786630.001752
146.586.5711830.00881715.39101.1305101.26620.1356960.00134
156.366.3516670.00833315.7199.7846899.91560.1309160.00131
1666.039650.0396516.0897.1175896.480.637576−0.00661
175.755.7781320.02813216.3494.4146793.9550.459675−0.00489
185.275.2733580.00335816.7688.3814888.32520.056278−0.00064
195.075.0808970.01089716.985.8671585.6830.184154−0.00215
204.794.7838870.00611317.181.8044881.9090.1045240.001276
214.564.5436930.01630717.2578.378778.660.2812980.003576
224.294.2706910.01930917.4174.3527374.68890.3361750.004501
233.833.8282460.00175417.6567.5685467.59950.0309640.000458
2400.004220.0042219.210.08107300.0810730
IAE (current)0.271318IAE (power)3.868108