Material properties used in FEA of the mandible. Orthotropic properties were used for cortical bone, while isotropic properties were used for cancellous bone, dentin, and the titanium plate. The x-direction is along the length of the mandible, the y-direction is normal to the bone plane, and the z-direction is their cross product.

Material propertiesSymphysisParasymphysisAngleRamusCondyleCoronoidCancellousDentinTitanium

(MPa)20 49221 72823 79324 60723 50028 0007 93017 600110 000
(MPa)12 09212 70012 75712 97112 65014 0007 93017 600110 000
(MPa)16 35017 82819 01418 35717 85017 5007 93017 600110 000
ν xy0.430.450.410.380.320.280.30.340.34
ν yz0.220.20.220.230.250.280.30.340.34
ν xz0.340.340.30.280.240.230.30.340.34
(MPa)5 3175 5335 4935 3865 5005 7503 0506 56741 045
(MPa)4 8255 0834 9865 0145 1505 3003 0506 56741 045
(MPa)6 9087 4507 5797 4077 1507 1503 0506 56741 045