Research Article

A Segmental Approach with SWT Technique for Denoising the EOG Signal

Table 1

RMSE values obtained between reference EOG signal and denoised EOG signals by increasing segments approach using SWT technique.

S. numberSegment of the signal (samples)EOG5 dB
SNR = 39.04 dB
EOG10 dB
SNR = 33.92 dB
EOG15 dB
SNR = 29.02 dB
EOG20 dB
SNR = 24.12 dB
EOG25 dB
SNR = 19.01 dB
RMSE (µV)RMSE (µV)RMSE (µV)RMSE (µV)RMSE (µV)

11:5128.388.398.819.7810.92
21:10245.946.056.637.529.35
31:15364.885.025.616.719.06
41:20484.254.415.056.258.91
51:25600.911.562.794.617.81
61:30720.941.572.784.607.89
71:35843.483.694.365.778.60
81:40963.273.494.205.608.49
91:46080.921.552.754.597.96
101:51201.461.932.974.738.04
111:56321.341.842.884.688.05
121:61441.381.872.914.708.07
131:66561.391.872.894.688.12
141:71682.032.373.234.958.25
151:76801.972.333.204.918.29
161:81921.531.992.944.798.22

Maximum value8.388.398.819.7810.92

Minimum value0.911.552.754.597.81

Mean (µV)2.753.124.005.558.50

Standard deviation (µV)2.151.971.741.430.78