Research Article

Transient Air-Water Flow and Air Demand following an Opening Outlet Gate

Table 3

Comparison of the results between the 2008 model tests and CFD.

(m)1.02.03.03.65
Test results (m3/s)106200306449
CFD results (m3/s)108203310435
(%)−1.9−1.5−1.0+3.1