Research Article
Measurements of Tool Wear Parameters Using Machine Vision System
Table 3
Comparison between the average wear width measured by the vision system and the digital microscope.
| Insert number | Wear zone image | Wear zone captured by vision system | Average wear width of inserts (mm) | Error (%) | Machine vision system | Digital microscope |
| 1 | | Negligible tool wear | — | — | | 2 | | | 0.108 | 0.103 | 4.6 | 3 | | | 0.155 | 0.149 | 3.9 | 4 | | | 0.169 | 0.162 | 4.1 | 5 | | | 0.183 | 0.178 | 2.7 | 6 | | | 0.206 | 0.199 | 3.4 | 7 | | | 0.208 | 0.201 | 3.4 | 8 | | | 0.278 | 0.274 | 1.4 | 9 | | | 0.286 | 0.273 | 4.5 | 10 | | | 0.35 | 0.339 | 3.1 | 11 | | | 0.46 | 0.438 | 4.8 | 12 | | | 0.521 | 0.515 | 1.2 |
|
|