Clinical Study

Effectiveness of the Gaze Direction Recognition Task for Chronic Neck Pain and Cervical Range of Motion: A Randomized Controlled Pilot Study

Table 3

Sequential reaction time data for the correct recognition of the experimenter’s direction of gaze and response accuracy in the GDR task group.

Experimental session
Session 1Session 2Session 3Session 4Session 5Session 6Session 7Session 8Session 9Session 10Session 11Session 12

Correct RT (msec)1722.91501.01465.91300.91361.31482.81411.61312.21316.01127.2*1263.81121.9*
SD558.7446.8345.4234.9380.9464.1287.2280.8190.9130.6323.390.7
Accuracy (%)93.094.493.096.395.694.195.698.197.899.699.3100.0
SD6.16.58.65.45.37.07.54.44.71.12.20.0

Correct RT = reaction times in correct recognition. Accuracy = response accuracy in the GDR task group. Sequential data from session 1 to session 12; mean and standard deviation ( ). *one-way ANOVA ( ).