Table of Contents Author Guidelines Submit a Manuscript
Radiology Research and Practice
Volume 2014 (2014), Article ID 425823, 4 pages
http://dx.doi.org/10.1155/2014/425823
Research Article

Dislocability of Localization Devices for Nonpalpable Breast Lesions: Experimental Results

1Department of Radiation Oncology, Charité School of Medicine and University Hospital, Campus Virchow-Klinikum, Augustenburger Platz 1, 13353 Berlin, Germany
2Department of Radiology, Charité School of Medicine and University Hospital, Campus Virchow-Klinikum, Augustenburger Platz 1, 13353 Berlin, Germany
3Krankenhaus St. Joseph-Stift, Institut für Radiologie, Schwachhauser Heerstraße 54, 28209 Bremen, Germany

Received 25 November 2013; Revised 1 February 2014; Accepted 4 February 2014; Published 6 March 2014

Academic Editor: Paul Sijens

Copyright © 2014 David Kaul et al. This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

Linked References

  1. T. A. Goedde, E. R. Frykberg, J. M. Crump, S. F. Lay, D. B. Turetsky, and S. S. Linden, “The impact of mammography on breast biopsy,” The American Surgeon, vol. 58, no. 11, pp. 661–666, 1992. View at Google Scholar · View at Scopus
  2. A. E. Papatestas, D. Hermann, G. Hermann, C. Tsevdos, and G. Lesnick, “Surgery for nonpalpable breast lesions,” Archives of Surgery, vol. 125, no. 3, pp. 399–402, 1990. View at Google Scholar · View at Scopus
  3. G. Q. della Rovere, J. R. Benson, M. Morgan, R. Warren, and A. Patel, “Localization of impalpable breast lesions—a surgical approach,” European Journal of Surgical Oncology, vol. 22, no. 5, pp. 478–482, 1996. View at Publisher · View at Google Scholar · View at Scopus
  4. M. J. Homer, “Transection of the localization hooked wire during breast biopsy,” The American Journal of Roentgenology, vol. 141, no. 5, pp. 929–930, 1983. View at Google Scholar · View at Scopus
  5. A. de Gaspari, P. Panizza, M. G. Rodighiero, S. Tacchini, and A. Del Maschio, “Complications of preoperative localization of nonpalpable breast lesion. Migration of the localization wire into the pleural cavity,” Radiologia Medica, vol. 89, no. 3, pp. 338–340, 1995. View at Google Scholar · View at Scopus
  6. A. W. Owen and E. N. Kumar, “Migration of localizing wires used in guided biopsy of the breast,” Clinical Radiology, vol. 43, no. 4, p. 251, 1991. View at Google Scholar · View at Scopus
  7. H. J. Langen, C. Walter, S. Ernst, H. Kugel, and K. Lackner, “MR-compatible and conventional localization wires in breast diagnosis: experimental studies on the dislocation and artefact size in MRT,” Rofo, vol. 170, no. 3, pp. 310–315, 1999. View at Google Scholar · View at Scopus
  8. E. J. Urrutia, M. C. Hawkins, B. G. Steinbach et al., “Retractable-barb needle for breast lesion localization: use in 60 cases,” Radiology, vol. 169, no. 3, pp. 845–847, 1988. View at Google Scholar · View at Scopus
  9. S. G. Schoenberger, J. C. Bamber, W. Rank, C. M. Sutherland, and R. L. Nichols, “A new coaxial needle for pre-operative localization of breast abnormalities,” British Journal of Radiology, vol. 64, no. 764, pp. 699–707, 1991. View at Google Scholar · View at Scopus