4DCT Scanning Technique for Primary Hyperparathyroidism: A Scoping Review

Academic Editor: Lorenzo Faggioni
Received02 Jan 2021
Revised11 Apr 2021
Accepted13 May 2021
Published21 May 2021

Abstract

Objective. 4DCT for the detection of (an) enlarged parathyroid(s) is a commonly performed examination in the management of primary hyperparathyroidism. Protocols are often institution-specific; this review aims to summarize the different protocols and explore the reported sensitivity and specificity of different 4DCT protocols as well as the associated dose. Materials and Methods. A literature study was independently conducted by two radiologists from April 2020 until May 2020 using the Medical Literature Analysis and Retrieval System Online (MEDLINE) database. Articles were screened and assessed for eligibility. From eligible studies, data were extracted to summarize different parameters of the scanning protocol and observed diagnostic attributes. Results. A total of 51 articles were included and 56 scanning protocols were identified. Most protocols use three (n = 25) or four different phases (n = 23). Almost all authors include noncontrast enhanced imaging and an arterial phase. Arterial images are usually obtained 25–30 s after administration of contrast, and less agreement exists concerning the timing of the venous phase(s). A mean contrast bolus of 100 mL is administered at 3-4 mL/s. Bolus tracking is not often used (n = 3). A wide range of effective doses are reported, up to 28 mSv. A mean sensitivity of 81.5% and a mean specificity of 86% are reported. Conclusion. Many different 4DCT scanning protocols for the detection of parathyroid adenomas exist in the literature. The number of phases does not appear to affect sensitivity or specificity. A triphasic approach, however, seems preferable, as three patterns of enhancement of parathyroid adenomas are described. Bolus tracking could help to reduce the variability of enhancement. Sensitivity and specificity also do not appear to be affected by other scan parameters like tube voltage or tube current. To keep the effective dose within limits, scanning at a lower fixed tube current seems preferable. Lowering tube voltage from 120 kV to 100 kV may yield similar image contrast but would also help lower the dose.

1. Introduction

Primary hyperparathyroidism is a common endocrine disease. In the case of an asymptomatic patient over the age of 50 without end-organ complications, conservative treatment can be assumed [1, 2]. The only cure for the disease is surgery, with resection of the affected gland(s). Bilateral exploration of the neck is the historical standard for treatment. In the last decades, however, a minimally invasive surgical approach has been made possible by more effective means of preoperative imaging combined with the development of rapid parathyroid hormone determination techniques allowing for intraoperative PTH monitoring [3].

The most accessible diagnostic technique is ultrasound because it is widely available at low cost, and it presents no adverse effects [4]. As a bonus, ultrasound is the preferred method of examination for the thyroid gland. This way parathyroid lesions can be differentiated from thyroid nodules and other thyroid pathologies. The sensitivity is very operator-dependent but can be as high as 84% in hands of an experienced ultrasonographer [5]. Color Doppler can be used to differentiate parathyroid lesions from other cervical masses, such as lymph nodes and thyroid nodules [6]. Small lesions (<5 mm) can be difficult to detect. False-negative results can occur, especially in the case of ectopic glands or in the presence of a large thyroid goiter [7].

Scintigraphy has the highest sensitivity compared to the other techniques: 88–90% and even higher sensitivity when combined with SPECT/SPECT-CT, the latter providing useful anatomical detail [8]. This technique is the method of choice when an ectopic localization is suspected or in patients having undergone prior neck surgery. The procedure relies on the uptake of 99mTechnetium (99mTc)-sestamibi in the overactivated mitochondria-rich oxyphil cells of the parathyroid gland and the difference in the rate of washout of this tracer with the thyroid. To overcome false positive results deriving from the uptake of sestamibi in solid thyroid nodules, another tracer can be administered that is exclusively taken up by the thyroid tissue, thereby permitting a subtraction of the thyroid. This method is known as the double-tracer technique and can achieve a specificity of over 90% [9].

MRI also allows for the evaluation of parathyroid disease. This technique, like ultrasound, is free of ionizing radiation but it is far a less available modality (a problem also found with scintigraphy). Due to the lack of ionizing radiation, MRI can be used without hesitation to detect ectopic glands. On a 1.5 Tesla system, the reported sensitivity of this technique is 80%; assumedly a better visualization on 3 Tesla systems can be obtained [1012].

Computed tomography (CT) of the neck without contrast is of no value since it is not possible to discern between parathyroid tissue, ectopic thyroid tissue, and lymph nodes. Four-dimensional CT (4DCT) combines three-dimensional imaging with the inclusion of time as the fourth dimension: this allows for an evaluation of the pattern of enhancement of lesions over time. By means of the evaluation of enhancement, abnormal parathyroid glands can be detected with a sensitivity of 85.7%: typical parathyroid adenomas are hypoattenuating to thyroid tissue on noncontrast enhanced imaging (NECT) and demonstrate avid arterial hyperenhancement during the arterial phase as well as rapid washout on the venous phase [13, 14]. 4DCT is also considered to be a useful technique in the case of ectopic glands or in the case of persistence/recurrence after the initial surgery.

Many different study protocols have been suggested by different authors over the past 15 years; protocols are often very institution-specific. We set out to examine the literature to review the different protocols and their reported sensitivity/specificity. The number of different phases used in a protocol as well as their timing could be a defining factor in sensitivity: as more phases are available, it could be argued that this would increase the sensitivity of the examination. Factors like tube current, tube voltage, and administration of contrast medium affect image noise and contrast and could therefore also have implications toward sensitivity. These factors also influence the effective dose, a key part to consider in multiphasic studies using ionizing radiation.

2. Materials and Methods

2.1. Research Question

This scoping review seeks to answer a multivalent research question. First, we want to establish the number of phases and their timing as used by different authors in the literature. Secondly, we wish to assess whether different protocols are associated with different sensitivity or specificity. We also look at other scanning protocol factors like tube current and tube voltage, contrast bolus volume, and timing: factors that not only can affect the sensitivity of the exam but also influence the effective dose, a key part to consider in multiphasic studies using ionizing radiation.

2.2. Search Strategy

This scoping review is reported according to the PRISMA Extension for Scoping Reviews (PRISMA-ScR) Checklist. A literature search was independently conducted by two radiologists using the MEDLINE database from April 2020 until May 2020 using the terms “4DCT” and “parathyroid.”

2.3. Inclusion and Exclusion Criteria

We included all peer-reviewed literature written in English or French. There was no limitation on the publication date. Exclusion criteria were articles written in a language other than English or French.

2.4. Data Selection and Charting Process

The two investigators independently screened the MEDLINE database for relevant articles. A first selection was made based on the title and abstract. Next, each investigator screened the obtained articles for relevancy, and a second selection was made. Finally, the remaining articles underwent a final screening: only studies citing information about the number of phases used in the scanning protocol were included in the scoping review. Forty articles were not relevant. Information regarding publication details (e.g., author, publication date) and study details (e.g., study design, scanning protocol) was obtained. Data was managed in Excel (Microsoft, Redmond, USA). Several scanning protocol factors were included in this review. We checked for the presence of a NECT in the study protocol. We evaluated the number of obtained phases and their timing: we defined a subdivision in an arterial phase (earlier than 40 seconds after contrast administration), a venous phase (40 seconds–70 seconds), a delayed venous phase (70 seconds–100 seconds), and a very delayed phase (later than 100 seconds). We evaluated whether this timing was expressed in absolute or relative relation to the onset of contrast administration; we expressed (where possible) all times in absolute relation to the administration of contrast. We also checked for the use of bolus tracking, which is defined as the use of a continuous density measurement in an arterial structure (usually at the level of the aortic arch) prior to obtaining the first arterial phase.

We also included other parameters of the scanning protocol: tube current is determined by the rate at which X-rays are produced in the X-ray tube (i.e., photons per second). It is expressed in milliampere (mA). Tube voltage is a parameter in direct relation to the number of X-rays produced. It is expressed in kilovolt (kV). The volume of the contrast bolus was included, as well as the injection speed expressed in mL/s. We included the effective dose, expressed in millisievert (mSv). Lastly, we included the reported sensitivity, PPV, specificity, and other related data provided.

3. Results

3.1. Identification of Potential Studies

The searches from the MEDLINE database hit a total of 91 records that were screened after the removal of duplicates. All articles were available to us in full-text format. The full-text screening stage led to 91 potential articles relevant to our scoping review. Additional articles were excluded after full-text assessment for the reasons mentioned in “Materials and Methods”. A flow chart is provided in Figure 1.

A total of 51 articles were included, as the authors of these had defined the number of phases and at least some of the parameters of the scanning protocol. These articles are listed chronologically in order of most recently published in Table 1. In the case of six studies, the authors defined two different protocols, thus amounting to 56 scanning protocols. These alternative protocols were added in Table 1 as secondary rows in relation to the first protocol.


ReferenceAuthorsYear publishedStudy designNECTTrackingContrast phase timingNumber of phasesArterial phaseVenous phaseDelayed phaseVery delayed phaseTube current (mA)Tube voltage (kV)Contrast volumeInjection speedEffective dose (mSv)Sensitivity/specificity/PPV/NPV/accuracy

[15]Vijayasarathi et al.2020Case seriesYesYesRelative325–30 s60–80 s?????

[16]Wojtczak et al.2020ReviewYesNoRelative425–30 s25–30 s85–90 s?????

[17]Acar et al.2020Retrospective studyYesNoAbsolute425 s40 s80 s??0.1 mL/kg??Sensitivity 50%
Specificity 100%
PPV 100%
NPV 85%
Accuracy 86.9%

[18]Zafereo et al.2019ReviewYesNoRelative325–30 s55–60 s????27–28
YesNoRelative325–30 s70 s????27–28

[19]Kedarisetty et al.2019Retrospective studyYesNoAbsolute325 s85 s??75 mL??Sensitivity 80%
Specificity 75%
PPV 92%
NPV 50%
Accuracy 79%

[20]Yeh et al.2019Retrospective studyYesNoRelative330 s60 s??75 mL4 mL/s22Sensitivity 79%
Specificity 96%
PPV 90%
NPV 90%

[21]Amadou et al.2019Retrospective studyYesNoAbsolute345 s70 s50–100120120 mL?10–27Sensitivity 75%
Specificity 40%
PPV 80%
NPV 33%

[22]Vu et al.2019Retrospective studyYesNoAbsolute425 s55 s85 s220130120 mL4 mL/s17.9

[23]Binks et al.2019Retrospective studyYesNoAbsolute325–30 s45–50 s????7.99–28Sensitivity 85.7%
PPV 94.7%

[24]Cunha-Bezerra et al.2018Retrospective studyYesYesRelative418–25 s48–55 s?120–2001202 mL/kg max 120 mL4-5 L/s?

[25]Tian et al.2018Retrospective cohort studyYesYesRelative3Aorta: 150HU30 s later??100 mL4 mL/s9.3Sensitivity 72.9%
Sensitivity 60% (persistent/recument disease)
Sensitivity 67.4% (multigland disease)

[26]Christakis et al.2017Retrospective studyYesNoAbsolute425 s????120 mL3 mL/s?Sensitivity 79%
Specificity 100%
PPV 100%
NPV 44%
Accuracy 82%

[27]Morón et al.2017Retrospective studyYesNoAbsolute225 s150–600120100 mL4 mL/s?Sensitivity 80%
Specificity 97%
PPV 89%
Accuracy 92%

[28]Goroshi et al.2017Retrospective studyYesNoAbsolute420 s60 s90 s140–22012060 mL4 mL/s18.9Left/right localization: Sensitivity 93% (hypercalcemic)
Quadrant localization: Sensitivity 90% (hypercalcemic)

[29]Taywade et al.2017Prospective studyYesNoAbsolute325 s80 s??75 mL4 mL/s11–13

[30]Zeina et al.2017Prospective studyYesNoAbsolute425 s60 s90 s400120120 mL4 mL/s?Accuracy 96%

[31]Sho et al.2016Prospective studyYesNoRelative325 s55 s230120100–120 mL3-4 mL/s?Sensitivity: 79% (multigland disease)
Specificity: 63%(multigland disease)
PPV:58% (multigland disease)

[32]Fitzgerald et al.2017Retrospective studyYesNoAbsolute330 s90 s180–60012075 mL3 mL/s10.4–28

[33]Rameau et al.2017Case seriesYesNoRelative325 s55 s150–300120100–120 mL4 mL/s?Sensitivity 84.6%
PPV 91.7%

[34]Ramirez et al.2016Retrospective studyYesNoAbsolute425 s55 s85 s-??120 mL4 mL/s14Sensitivity 93%
PPV:96%
YesNoAbsolute225 s??120 mL4 mL/s6.8Sensitivity 97%
PPV:94%

[35]Forghani et al.2016Retrospective studyYesNoAbsolute425 s55 s85 s??100 mL3.5 mL/s2.4–4.1

[36]Lee et al.2016Retrospective studyYesNoAbsolute430 s60 s90 s140–24012090 mL5 mL/s10.9

[37]Hinsin et al.2015Case seriesYesNoAbsolute430 s80 s??75 mL3 mL/s13.8Left/right localization: Sensitivity 84.2% (hypercalcemic)
Left/right localization: Specificity 81.8% (hypercalcemic)
Quadrant localization: Sensitivity 76.5% (hypercalcemic)
Quadrant localization: Specificity 91.59% (hypercalcemic)

[38]Bahl et al.2015Retrospective studyYesNoAbsolute325 s45 s70 s100–70012075 mL4 mL/s28Sensitivity 85%
Sensitivity: 94% (single gland disease)
Sensitivity: 59% (multigland disease)

[39]Boury2015ReviewYesNoAbsolute345 s70 s???3 mL/s?

[40]Hoang et al.2015Phantom studyYesNoAbsolute325 s80 s100–50012075 mL4 mL/s28

[41]Lundstroem et al.2016Retrospective studyYesNoAbsolute522 s52 s82 s122 s200120100 mL3.5 mL/s5.56–10.4Left/right localization: Sensitivity 84% (hypercalcemic)
Left/right localization: Specificity 76% (hypercalcemic)
Quadrant localization: Sensitivity 55% (hypercalcemic)
Quadrant localization: Specificity 50% (hypercalcemic)

[42]Seeliger et al.2015Prospective studyYesNoAbsolute425 s50 s80 s250120120 mL2 mL/s?PPV 93%

[43]Cham et al.2015Retrospective studyYesNoRelative325–34 s55–64 s230120100–120 mL??

[44]Day et al.2015Retrospective studyYesNoAbsolute430 s60 s90 s100–750120100,L3 mL/s?Sensitivity 93%
PPV 80%

[45]Campbell et al.2015Retrospective studyYesNoAbsolute250 s100–44012075–100 mL?5.2Left/right localization: Sensitivity 77% (hypercalcemic)
Left/right localization: Specificity 87% (hypercalcemic)
Quadrant localization: Sensitivity 58% (hypercalcemic)
Quadrant localization: Specificity 91% (hypercalcemic)

[46]Sepahdari et al.2015Retrospective studyYesNoAbsolute325 s55 s230120100–120 mL3–4 mL/s?Sensitivity 77%
YesNoAbsolute325 s80 s230120100–120 mL3–4 mL/s?Sensitivity: 95% (single gland disease)
Sensitivity: 55% (multigland disease)

[47]Suh et al.2015Case seriesYesNoAbsolute430 s60 s90 s140–24012090 mL??Sensitivity 92.1%
Specificity 95.6%
PPV 87.5%
NPV 97.3%
Accuracy 94.7%

[48]Ginsburg et al.2015Retrospective studyYesNoAbsolute425 s55 s85 s200120120 m4 mL/s?Sensitivity 50%
PPV 100%
Accuracy 54.5%

[49]Raghavan et al.2014Retrospective studyYesNoAbsolute425 s50 s80 s50–400120120 mL4 mL/s?Accuracy, sensitivity, and specificity for localization and lateralization of the arterial phase alone were comparable with the full complement of 4 phases

[50]Brown et al.2015Retrospective cohort studyYesNoAbsolute334 s68 s??70 mL3 mL/s7.99 mSv (3 phases)Sensitivity 92%
10.88,Sv(4 phases)PPV 89%

[14]Hoang et al.2014Case seriesYesNoAbsolute325 s80 s100–40012075 mL4 mL/s?

[51]Hunter et al.2014Retrospective studyYesNoRelative330 s60 s180–300140100 mL4 mL/s?Sensitivity 94%
Specificity 98.3%
PPV 96.7%
NPV 97.1%

[52]Bahl et al.2014Retrospective studyNoNoAbsolute220 s70 s100–400120100 mL4 mL/s?
YesNoAbsolute325 s80 s100–70012075 mL4 mL/s?

[53]Kely et al.2014Retrospective studyYesNoRelative430 s45 s90 s180–300140100 mL4 mL/s28PPV 85.8%
Accuracy 77.9%
YesNoRelative330 s45 s180–300140100 mL4 mL/s21PPV 89%
Accuracy 87.1%

[54]Sepahdari et al.2013Retrospective studyYesNoRelative325–34 s55–84 s230120100–120 mL3–4 mL/s2.2 mSv/phasesInterobserver comparison
Sensitivity 73% vs 55%
Specificity 88% vs 100%
PPV 91% vs 100%
NPV 64% vs 52%
Accuracy 78% vs 70%

[55]Hunter et al.2012Retrospective studyYesNoRelative425 s70–73 s130–133 s240140120 mL4 mL/s21 mSv (3 phases)Left/right localization: Accuracy 93.7%
27 mSv (4 phases)Quadrant localization: Accuracy 86.6%

[56]Mahajan et al.2012?YesNoAbsolute430 s60 s90 s??80 mL?10.4

[57]Gafton et al.2012Case seriesNoNoAbsolute225 s80 s?120120 mL3 mL/s?

[58]Kutler et al.2011Retrospective studyYesNoAbsolute250 s220–320120125 mL3 mL/s12.2

[59]Eichhom-Wharry et al.2011Retrospective studyNoNo?218 sImmediately??100 mL??Accuracy 73%
NoNo?222 s (>55y)Immediately??100 mL??

[13]Starker et al.2011Retrospective studyYesNoAbsolute430 s60 s120 s100–750120100 mL3 mL/s?Left/right localization: Sensitivity 93.9%
Left/right localization: PPV 93.5%
Quadrant localization: Sensitivity 85.7%
Quadrant localization: PPV 84.9%

[60]Beland et al.2011Retrospective studyYesNoAbsolute430 s60 s90 s100–750120???Sensitivity 82%
Specificity 92%

[61]Lubitz et al.2010Retrospective studyYesNoRelative430 s60 s105 s180–300140100 mL?10Left/right localization: Sensitivity 73%
Quadrant localization: Sensitivity 60%

[62]Mortenson et al.2008Retrospective studyYesNoRelative425 s55 s85 s??120 mL4 mL/s?Sensitivity 88%

[63]Rodgers et al.2006Mixed prospective and retrospective studyYesNo?325 s?220140120 mL3 mL/s?Sensitivity 88%
Quadrant localization: Sensitivity 70%

3.2. Characteristics of the Included Studies

The peer-reviewed literature on the subject of 4DCT for the detection of parathyroid adenomas is recent: the concept of 4DCT for the detection of parathyroid adenomas was coined in 2006 by Rodgers et al. Among the included studies, 45% were published in the last five years. Most studies (76.5%) are retrospective studies.

3.3. Number of Phases

Most authors use a triphasic approach: 25 study protocols were described in this manner. A four-phasic approach is almost as prevalent; 23 study protocols were described in this manner. Far less common are biphasic studies: only 7 of these protocols could be identified. One study was unique since the authors made use of a five-phasic approach.

3.4. Use of a Noncontrast Enhanced Phase

Fifty-two out of 56 study protocols include a noncontrast enhanced phase (NECT), before administration of contrast medium. Only 4 protocols were identified in which the authors did not acquire a NECT; these protocols were all two-phasic in nature.

3.5. Contrast Phase Timing and Bolus Tracking

Only three authors use bolus tracking. All other authors opt for a fixed time interval after the start of contrast bolus administration before obtaining the first contrast phase, almost always an arterial phase.

Many authors do not provide definitions for the later phases in absolute terms (relation to the start of contrast bolus administration) and refer to relative intervals between the different phases. Since many authors do not describe pitch and rotation speed or refer to an exact scan length, the scan time of the different phases themselves is often unclear. This further complicates the definition of an exact timeframe. We expressed (where possible) all times in absolute relation to the onset of contrast administration; some error can be expected on a conversion. A graphic overview of the timing of the different phases of the selected studies is presented in Figure 2; this is in relation to the number of protocols citing these relevant time points.

3.6. Use of an Arterial Phase

Except for four studies, all cited studies choose to obtain an arterial phase. In the case of 25 different studies, the arterial images were obtained 25 s after contrast administration; in 13 studies, the authors proposed scanning after 30 s. Five other authors stated that the arterial images were obtained by scanning after 25–30 s. Forty-two protocols then perform arterial scanning after 25 to 30 s.

3.7. Use of Other Phases

The venous phase is obtained most often and can be acquired as early as 45 seconds up to 70 seconds after administration of contrast. The delayed venous phase is less popular and is usually acquired between 70 seconds and as late as 90 seconds after administration of contrast. Rarely, authors also acquire an even more delayed phase: later than 100 seconds after bolus administration and even up to 130 seconds.

3.8. Contrast Administration

Most studies define the used contrast medium, bolus volume, and injection speed. A mean volume of 100 mL contrast is administered, most commonly at 3 or 4 mL/s. Two authors define the contrast volume in function of the patient’s weight.

3.9. Effective Dose

Only 24 authors present data concerning the effective dose. The described doses are wide-ranging, with the lowest dose reported at 5.5 mSv and an upper limit of 28 mSv. The mean effective dose for all relevant studies combined is calculated at 15.96 mSv. 27 authors do not discuss dose limits.

The mean effective dose for the three biphasic studies with available data is calculated at 8.1 mSv. For the three- and four-phasic studies, the mean effective dose is higher, 18.1 mSv and 15.4 mSv, respectively. The authors of the only five-phasic study report an effective dose range of 5.6–10.4 mSv.

3.10. Appraisal of Sensitivity/Specificity

All included studies were assessed for the quality of the reported findings. 74.5% of the included studies report on sensitivity and specificity. Some studies (14%) do not refer to general sensitivity but report on the sensitivity of lateralization or correct selection of the diseased quadrant.

We find a mean sensitivity (n = 23) of 81.5% for the detection of parathyroid adenomas using 4DCT. Only two studies report a lower sensitivity of 50%; both studies are four-phasic studies. We find a mean PPV (n = 17) of 90%. Less data is available on specificity (n = 11), and the mean specificity is calculated at 86%.

4. Discussion

Typical parathyroid adenomas are hypoattenuating to thyroid tissue on NECT and demonstrate avid arterial enhancement during the arterial phase as well as rapid washout on the venous phase. The arterial phase is the most important, as adenomas can be visualized as hyperenhancing nodules in characteristic locations. In Figure 3, we provide an example of a parathyroid adenoma behaving accordingly during all three phases. Unfortunately, for approximately one-third of adenomas, the lesion will prove to be isoattenuating to the thyroid on arterial and venous phases [15].

Most authors agree to include a noncontrast enhanced phase. This phase does seem to be important in the diagnosis of parathyroid adenomas, as the study by Bahl et al. [38] identifies a type C pattern of enhancement. These lesions mimic thyroid tissue and can only be discerned by the use of noncontrast-enhanced imaging since these lesions should be lower in density compared to the thyroid on the noncontrast enhanced series. Almost all authors choose to include an arterial phase. According to Bahl et al., this is necessary to diagnose type A lesions, which demonstrate a higher peak enhancement compared to the thyroid in the arterial phase. A venous or delayed venous phase is commonly used. According to Bahl et al., this is necessary to diagnose type B lesions, which demonstrate a lower enhancement compared to the thyroid in the venous phase.

Most authors opt for a delay of 25 up to 30 seconds for the arterial phase after contrast administration. There is more variance concerning the timing of the venous phases, with some authors scanning as early as 40 seconds after administration of contrast and others no less than 50 seconds later. Other authors even prefer very delayed venous phases. We find no difference regarding the sensitivity or specificity of 4DCT in comparison to the number of phases or their timing. The two studies with the lowest sensitivity are both four-phasic studies, with numerous three-phasic studies reporting higher sensitivity.

Only three authors use bolus tracking to optimize the scanning delay, although this could easily be implemented. If the arterial peak enhancement of the adenoma should prove to be a short-lived effect, scanning at a fixed interval of time might risk missing the diagnosis. This would prove especially true in older patients with suboptimal cardiac output, as the arterial phase could be performed too early in these cases. Bolus tracking at the level of the aortic arch would allow for the arterial and later phases to be obtained at a variable time interval, with reduced variability of arterial enhancement and less risk of scanning prematurely. Bolus tracking is commonly used in clinical practice, without significant dose effect [64].

Regarding contrast administration, the variance between the reviewed studies is limited. Administered bolus volumes are situated between 75 mL and 120 mL with a mean volume of 100 mL. Injection speed varies mostly between 3 and 4 mL/s. A contrast bolus with a lower volume or at a lower injection speed may affect lesion enhancement and the timing of said enhancement. No difference regarding sensitivity or specificity of 4DCT is found, however, for different volumes or injection speeds.

What proves striking is that 27 out of 51 authors do not mention effective dose when discussing a multiphasic CT scan of the neck. The mean effective dose for the 24 studies that do comment on patient dose is calculated at 15.96 mSv. The described dose limits are wide-ranging, with an upper limit of 28 mSv. These upper values should be considered as very high and place direct limits on the number of phases. As a limitation, it should be noted that it is difficult to calculate a correct effective organ dose. The presence of an iodinated contrast medium is a known factor that increases organ dose, yet this has not been factored into any known conversion method [65].

The mean effective dose is the lowest for biphasic studies, as could be expected. The mean effective dose for the three studies with available effective dose data is calculated at 8.1 mSv. For the more popular three- and four-phasic studies, the mean effective dose is higher, but the mean effective dose for the four-phasic studies appears lower in comparison to the three-phasic studies (15.4 mSv versus 18.1 mSv). This is probably because of lower tube current settings, an effect that can also be observed in the only five-phasic study. Here, a low mean effective dose range of 5.6–10.4 mSv is reported, probably because the authors do not use automatic tube current modulation but instead opt for a fixed tube current of 200 mA.

Changes in tube current will affect image noise: higher mA settings will result in lower noise. Changes in tube voltage will affect the amount of contrast in the resultant image: higher kV settings will result in an increase in contrast. Since increasing the tube current improves image quality by reducing noise without affecting image contrast, it can be argued that to keep the effective dose for classic 4DCT within acceptable levels, a lower fixed tube current should be preferred. Most protocols utilize a 120 kV tube voltage. Since diagnosis relies primarily on enhancement after contrast, it can be suggested that scanning at 100 kV tube voltage would yield similar image contrast, but at a lower effective dose [66]. Again, regarding tube parameters, no difference in sensitivity or specificity is found for different values.

5. Conclusion

Many different 4DCT scanning protocols for the detection of parathyroid adenomas exist in the literature. We find a mean sensitivity of 81.5% and a mean specificity of 86%. The number of phases does not appear to affect sensitivity or specificity. A triphasic approach, however, seems preferable, as three patterns of enhancement of parathyroid adenomas are described and require nonenhanced imaging as well as an arterial and a venous series. Arterial images are usually obtained 25–30 s after administration of contrast, and less agreement exists concerning the timing of the venous phase(s). A mean contrast bolus of 100 mL is administered at 3–4 mL/s. Bolus tracking is not often used but could help to reduce the variability of enhancement. Sensitivity and specificity do not appear to be affected by other scan parameters like tube voltage or tube current. To keep the effective dose within limits, scanning at a lower fixed tube current seems preferable. Lowering tube voltage from 120 kV to 100 kV may yield similar image contrast but would also help lower the dose.

Data Availability

No data were used to support this study.

Conflicts of Interest

The authors declare that they have no conflicts of interest.

Authors’ Contributions

SR reviewed the literature and wrote the text. MT revised the final manuscript.

References

  1. J. P. Bilezikian, M. L. Brandi, R. Eastell et al., “Guidelines for the management of asymptomatic primary hyperparathyroidism: summary statement from the Fourth International Workshop,” The Journal of Clinical Endocrinology & Metabolism, vol. 99, no. 10, pp. 3561–3569, 2014. View at: Publisher Site | Google Scholar
  2. S. J. Silverberg, B. L. Clarke, M. Peacock et al., “Current issues in the presentation of asymptomatic primary hyperparathyroidism: proceedings of the Fourth International Workshop,” The Journal of Clinical Endocrinology & Metabolism, vol. 99, no. 10, pp. 3580–3594, 2014. View at: Publisher Site | Google Scholar
  3. R. Udelsman, G. Åkerström, C. Biagini et al., “The surgical management of asymptomatic primary hyperparathyroidism: proceedings of the Fourth International Workshop,” The Journal of Clinical Endocrinology & Metabolism, vol. 99, no. 10, pp. 3595–3606, 2014. View at: Publisher Site | Google Scholar
  4. S. Y. Morita, H. Somervell, C. B. Umbricht, A. P. B. Dackiw, and M. A. Zeiger, “Evaluation for concomitant thyroid nodules and primary hyperparathyroidism in patients undergoing parathyroidectomy or thyroidectomy,” Surgery, vol. 144, no. 6, pp. 862–867, 2008. View at: Publisher Site | Google Scholar
  5. G. M. Vitetta, P. Neri, A. Chiecchio et al., “Role of ultrasonography in the management of patients with primary hyperparathyroidism: retrospective comparison with technetium-99m sestamibi scintigraphy,” Journal of Ultrasound, vol. 17, no. 1, pp. 1–12, 2014. View at: Publisher Site | Google Scholar
  6. Z. Devcic, R. B. Jeffrey, A. Kamaya, and T. S. Desser, “The elusive parathyroid adenoma,” Ultrasound Quarterly, vol. 29, no. 3, pp. 179–187, 2013. View at: Publisher Site | Google Scholar
  7. E. Berber, R. T. Parikh, N. Ballem, C. N. Garner, M. Milas, and A. E. Siperstein, “Factors contributing to negative parathyroid localization: an analysis of 1000 patients,” Surgery, vol. 144, no. 1, pp. 74–79, 2008. View at: Publisher Site | Google Scholar
  8. C. Guerin, A. Lowery, S. Gabriel et al., “Preoperative imaging for focused parathyroidectomy: making a good strategy even better,” European Journal of Endocrinology, vol. 172, no. 5, pp. 519–526, 2015. View at: Publisher Site | Google Scholar
  9. E. Hindié, P. Zanotti-Fregonara, A. Tabarin et al., “The role of radionuclide imaging in the surgical management of primary hyperparathyroidism,” Journal of Nuclear Medicine, vol. 56, no. 5, pp. 737–744, 2015. View at: Publisher Site | Google Scholar
  10. E. L. Hänninen, T. J. Vogl, T. Steinmüller, J. Ricke, P. Neuhaus, and R. Felix, “Preoperative contrast-enhanced MRI of the parathyroid glands in hyperparathyroidism,” Investigative Radiology, vol. 35, no. 7, pp. 426–430, 2000. View at: Publisher Site | Google Scholar
  11. A. M. Grayev, L. R. Gentry, M. J. Hartman, H. Chen, S. B. Perlman, and S. B. Reeder, “Presurgical localization of parathyroid adenomas with magnetic resonance imaging at 3.0 T: an adjunct method to supplement traditional imaging,” Annals of Surgical Oncology, vol. 19, no. 3, pp. 981–989, 2012. View at: Publisher Site | Google Scholar
  12. B. Sacconi, R. Argirò, D. Diacinti et al., “MR appearance of parathyroid adenomas at 3 T in patients with primary hyperparathyroidism: what radiologists need to know for pre-operative localization,” European Radiology, vol. 26, no. 3, pp. 664–673, 2016. View at: Publisher Site | Google Scholar
  13. L. F. Starker, A. Mahajan, P. Björklund, G. Sze, R. Udelsman, and T. Carling, “4D parathyroid CT as the initial localization study for patients with de novo primary hyperparathyroidism,” Annals of Surgical Oncology, vol. 18, no. 6, pp. 1723–1728, 2011. View at: Publisher Site | Google Scholar
  14. J. K. Hoang, W.-k. Sung, M. Bahl, and C. D. Phillips, “How to perform parathyroid 4D CT: tips and traps for technique and interpretation,” Radiology, vol. 270, no. 1, pp. 15–24, 2014. View at: Publisher Site | Google Scholar
  15. A. Vijayasarathi, S. Karnezis, A. Azizyan, N. Salamon, and A. Sepahdari, “4D CT parathyroid for the general radiologist: a pictorial essay of illustrative cases,” Current Problems in Diagnostic Radiology, vol. 20, pp. 30046–30053, 2020. View at: Google Scholar
  16. B. Wojtczak, J. Syrycka, K. Kaliszewski, J. Rudnicki, M. Bolanowski, and M. Barczyński, “Surgical implications of recent modalities for parathyroid imaging,” Gland Surgery, vol. 9, no. 2, pp. S86–S94, 2020. View at: Publisher Site | Google Scholar
  17. N. Acar, M. Haciyanli, M. Coskun et al., “Diagnostic value of four-dimensional computed tomography and four-dimensional magnetic resonance imaging in primary hyperparathyroidism when first-line imaging was inadequate,” The Annals of The Royal College of Surgeons of England, vol. 102, no. 4, pp. 294–299, 2020. View at: Publisher Site | Google Scholar
  18. M. Zafereo, J. Yu, P. Angelos et al., “American head and neck society endocrine surgery section update on parathyroid imaging for surgical candidates with primary hyperparathyroidism,” Head & Neck, vol. 41, no. 7, pp. 2398–2409, 2019. View at: Publisher Site | Google Scholar
  19. S. Kedarisetty, C. Fundakowski, K. Ramakrishnan, and S. Dadparvar, “Clinical value of Tc99m-MIBI SPECT/CT versus 4D-CT or US in management of patients with hyperparathyroidism,” Ear, Nose & Throat Journal, vol. 98, no. 3, pp. 149–157, 2019. View at: Publisher Site | Google Scholar
  20. R. Yeh, Y.-K. D. Tay, G. Tabacco et al., “Diagnostic performance of 4D CT and sestamibi SPECT/CT in localizing parathyroid adenomas in primary hyperparathyroidism,” Radiology, vol. 291, no. 2, pp. 469–476, 2019. View at: Publisher Site | Google Scholar
  21. C. Amadou, G. Bera, M. Ezziane et al., “18F-fluorocholine PET/CT and parathyroid 4D computed tomography for primary hyperparathyroidism: the challenge of reoperative patients,” World Journal of Surgery, vol. 43, no. 5, pp. 1232–1242, 2019. View at: Publisher Site | Google Scholar
  22. T. H. Vu, D. Schellingerhout, N. Guha-Thakurta et al., “Solitary parathyroid adenoma localization in technetium Tc99m Sestamibi SPECT and multiphase multidetector 4D CT,” American Journal of Neuroradiology, vol. 40, no. 1, pp. 142–149, 2019. View at: Publisher Site | Google Scholar
  23. M. Binks, D. Burrows, and D. Littlejohn, “A rural perspective on minimally invasive parathyroidectomy: optimal preoperative imaging and patient outcomes,” ANZ Journal of Surgery, vol. 89, no. 1-2, pp. 43–47, 2019. View at: Publisher Site | Google Scholar
  24. P. Cunha-Bezerra, R. Vieira, F. Amaral, H. Cartaxo, T. Lima, and U. Montarroyos, “Better performance of four-dimension computed tomography as a localization procedure in normocalcemic primary hyperparathyroidism,” Journal of Medical Imaging and Radiation Oncology, vol. 15, 2018. View at: Google Scholar
  25. Y. Tian, S. T. Tanny, P. Einsiedel et al., “Four-dimensional computed tomography: clinical impact for patients with primary hyperparathyroidism,” Annals of Surgical Oncology, vol. 25, no. 1, pp. 117–121, 2018. View at: Publisher Site | Google Scholar
  26. I. Christakis, T. Vu, H. H. Chuang et al., “The diagnostic accuracy of neck ultrasound, 4D-Computed tomographyand sestamibi imaging in parathyroid carcinoma,” European Journal of Radiology, vol. 95, pp. 82–88, 2017. View at: Publisher Site | Google Scholar
  27. F. Morón, A. Delumpa, J. Chetta, D. Guffey, and D. Dunaway, “Single phase computed tomography is equivalent to dual phase method for localizing hyperfunctioning parathyroid glands in patients with primary hyperparathyroidism: a retrospective review,” PeerJ, vol. 5, Article ID e3586, 2017. View at: Publisher Site | Google Scholar
  28. M. Goroshi, A. R. Lila, S. S. Jadhav et al., “Percentage arterial enhancement: an objective index for accurate identification of parathyroid adenoma/hyperplasia in primary hyperparathyroidism,” Clinical Endocrinology, vol. 87, no. 6, pp. 791–798, 2017. View at: Publisher Site | Google Scholar
  29. S. K. Taywade, N. A. Damle, A Behera et al., “Comparison of 18F-fluorocholine positron emission tomography/computed tomography and four-dimensional computed tomography in the preoperative localization of parathyroid adenomas-initial results,” Indian Journal of Endocrinology and Metabolism, vol. 21, no. 3, pp. 399–403, 2017. View at: Publisher Site | Google Scholar
  30. A. R. Zeina, H. Nakar, N Reindorp D et al., “Four-dimensional computed tomography (4DCT) for preoperative localization of parathyroid adenomas,” The Israel Medical Association Journal: IMAJ, vol. 19, no. 4, pp. 216–220, 2017. View at: Google Scholar
  31. S. Sho, M. Yilma, M. W. Yeh et al., “Prospective validation of two 4D-CT-based scoring systems for prediction of multigland disease in primary hyperparathyroidism,” American Journal of Neuroradiology, vol. 37, no. 12, pp. 2323–2327, 2016. View at: Publisher Site | Google Scholar
  32. R. T. Fitzgerald, M. Kuruva, R. David et al., “Characterization of thyroid nodules by 4-dimensional computed tomography,” Journal of Computer Assisted Tomography, vol. 41, no. 2, pp. 195–198, 2017. View at: Publisher Site | Google Scholar
  33. A. Rameau, S. Eng, J. Vu, R. Saket, P. Jun, and M. Friduss, “Four-dimensional computed tomography scan utility in parathyroidectomy for primary hyperparathyroidism with low baseline intact parathyroid hormone,” The Laryngoscope, vol. 127, no. 6, pp. 1476–1482, 2017. View at: Publisher Site | Google Scholar
  34. A. G. Ramirez, A. L. Shada, A. N. Martin et al., “Clinical efficacy of 2-phase versus 4-phase computed tomography for localization in primary hyperparathyroidism,” Surgery, vol. 160, no. 3, pp. 731–737, 2016. View at: Publisher Site | Google Scholar
  35. R. Forghani, M. Roskies, X. Liu et al., “Dual-energy CT characteristics of parathyroid adenomas on 25-and 55-second 4D-CT acquisitions,” Journal of Computer Assisted Tomography, vol. 40, no. 5, pp. 806–814, 2016. View at: Publisher Site | Google Scholar
  36. E. K. Lee, T. J. Yun, J.-h. Kim et al., “Effect of tumor volume on the enhancement pattern of parathyroid adenoma on parathyroid four-dimensional CT,” Neuroradiology, vol. 58, no. 5, pp. 495–501, 2016. View at: Publisher Site | Google Scholar
  37. A. M. Hinson, D. R. Lee, B. A. Hobbs, R. T. Fitzgerald, D. L. Bodenner, and B. C. Stack, “Preoperative 4D CT localization of nonlocalizing parathyroid adenomas by ultrasound and SPECT-CT,” Otolaryngology-Head and Neck Surgery, vol. 153, no. 5, pp. 775–778, 2015. View at: Publisher Site | Google Scholar
  38. M. Bahl, A. R. Sepahdari, J. A. Sosa, and J. K. Hoang, “Parathyroid adenomas and hyperplasia on four-dimensional CT scans: three patterns of enhancement relative to the thyroid gland justify a three-phase protocol,” Radiology, vol. 277, no. 2, pp. 454–462, 2015. View at: Publisher Site | Google Scholar
  39. S. Boury, “New methods for parathyroid imaging: sonography, 4D CT, MRI,” Annales d'Endocrinologie, vol. 76, no. 2, pp. 148–152, 2015. View at: Publisher Site | Google Scholar
  40. J. K. Hoang, R. E. Reiman, G. B. Nguyen et al., “Lifetime attributable risk of cancer from radiation exposure during parathyroid imaging: comparison of 4D CT and parathyroid scintigraphy,” American Journal of Roentgenology, vol. 204, no. 5, pp. W579–W585, 2015. View at: Publisher Site | Google Scholar
  41. A. K. Lundstroem, W. Trolle, C. H. Soerensen, and P. S. Myschetzky, “Preoperative localization of hyperfunctioning parathyroid glands with 4D-CT,” European Archives of Oto-Rhino-Laryngology, vol. 273, no. 5, pp. 1253–1259, 2016. View at: Publisher Site | Google Scholar
  42. B. Seeliger, P. F. Alesina, J.-A. Koch, J. Hinrichs, B. Meier, and M. K. Walz, “Diagnostic value and clinical impact of complementary CT scan prior to surgery for non-localized primary hyperparathyroidism,” Langenbeck’s Archives of Surgery, vol. 400, no. 3, pp. 307–312, 2015. View at: Publisher Site | Google Scholar
  43. S. Cham, A. R. Sepahdari, K. E. Hall, M. W. Yeh, and A. Harari, “Dynamic parathyroid computed tomography (4DCT) facilitates reoperative parathyroidectomy and enables cure of missed hyperplasia,” Annals of Surgical Oncology, vol. 22, no. 11, pp. 3537–3542, 2015. View at: Publisher Site | Google Scholar
  44. K. M. Day, M. Elsayed, M. D. Beland, and J. M. Monchik, “The utility of 4-dimensional computed tomography for preoperative localization of primary hyperparathyroidism in patients not localized by sestamibi or ultrasonography,” Surgery, vol. 157, no. 3, pp. 534–539, 2015. View at: Publisher Site | Google Scholar
  45. M. J. Campbell, P. Sicuro, A. Alseidi, C. C. Blackmore, and J. A. Ryan, “Two-phase (low-dose) computed tomography is as effective as 4D-CT for identifying enlarged parathyroid glands,” International Journal of Surgery, vol. 14, pp. 80–84, 2015. View at: Publisher Site | Google Scholar
  46. A. R. Sepahdari, M. Bahl, A. Harari, H. J. Kim, M. W. Yeh, and J. K. Hoang, “Predictors of multigland disease in primary hyperparathyroidism: a scoring system with 4D-CT imaging and biochemical markers,” American Journal of Neuroradiology, vol. 36, no. 5, pp. 987–992, 2015. View at: Publisher Site | Google Scholar
  47. Y. J. Suh, J. Y. Choi, S.-j. Kim et al., “Comparison of 4D CT, ultrasonography, and 99mTc sestamibi SPECT/CT in localizing single-gland primary hyperparathyroidism,” Otolaryngology-Head and Neck Surgery, vol. 152, no. 3, pp. 438–443, 2015. View at: Publisher Site | Google Scholar
  48. M. Ginsburg, G. A. Christoforidis, S. P. Zivin et al., “Adenoma localization for recurrent or persistent primary hyperparathyroidism using dynamic four-dimensional CT and venous sampling,” Journal of Vascular and Interventional Radiology, vol. 26, no. 1, pp. 79–86, 2015. View at: Publisher Site | Google Scholar
  49. P. Raghavan, C. R. Durst, D. A. Ornan et al., “Dynamic CT for parathyroid disease: are multiple phases necessary?” American Journal of Neuroradiology, vol. 35, no. 10, pp. 1959–1964, 2014. View at: Publisher Site | Google Scholar
  50. S. J. Brown, J. C. Lee, J. Christie et al., “Four-dimensional computed tomography for parathyroid localization: a new imaging modality,” ANZ Journal of Surgery, vol. 85, no. 6, pp. 483–487, 2015. View at: Publisher Site | Google Scholar
  51. G. J. Hunter, D. T. Ginat, H. R. Kelly, E. F. Halpern, and L. M. Hamberg, “Discriminating parathyroid adenoma from local mimics by using inherent tissue attenuation and vascular information obtained with four-dimensional CT: formulation of a multinomial logistic regression model,” Radiology, vol. 270, no. 1, pp. 168–175, 2014. View at: Publisher Site | Google Scholar
  52. M. Bahl, M. Muzaffar, G. Vij, J. A. Sosa, K. R. Choudhury, and J. K. Hoang, “Prevalence of the polar vessel sign in parathyroid adenomas on the arterial phase of 4D CT,” American Journal of Neuroradiology, vol. 35, no. 3, pp. 578–581, 2014. View at: Publisher Site | Google Scholar
  53. H. R. Kelly, L. M. Hamberg, and G. J. Hunter, “4D-CT for preoperative localization of abnormal parathyroid glands in patients with hyperparathyroidism: accuracy and ability to stratify patients by unilateral versus bilateral disease in surgery-naïve and re-exploration patients,” American Journal of Neuroradiology, vol. 35, no. 1, pp. 176–181, 2014. View at: Publisher Site | Google Scholar
  54. A. R. Sepahdari, M. W. Yeh, D. Rodrigues, S. N. Khan, and A. Harari, “Three-phase parathyroid 4-dimensional computed tomography initial experience,” Journal of Computer Assisted Tomography, vol. 37, no. 4, pp. 511–517, 2013. View at: Publisher Site | Google Scholar
  55. G. J. Hunter, D. Schellingerhout, T. H. Vu, N. D. Perrier, and L. M. Hamberg, “Accuracy of four-dimensional CT for the localization of abnormal parathyroid glands in patients with primary hyperparathyroidism,” Radiology, vol. 264, no. 3, pp. 789–795, 2012. View at: Publisher Site | Google Scholar
  56. A. Mahajan, L. F. Starker, M. Ghita, R. Udelsman, J. A. Brink, and T. Carling, “Parathyroid four-dimensional computed tomography: evaluation of radiation dose exposure during preoperative localization of parathyroid tumors in primary hyperparathyroidism,” World Journal of Surgery, vol. 36, no. 6, pp. 1335–1339, 2012. View at: Publisher Site | Google Scholar
  57. A. R. Gafton, C. M. Glastonbury, J. D. Eastwood, and J. K. Hoang, “Parathyroid lesions: characterization with dual-phase arterial and venous enhanced CT of the neck,” American Journal of Neuroradiology, vol. 33, no. 5, pp. 949–952, 2012. View at: Publisher Site | Google Scholar
  58. D. I. Kutler, R. Moquete, E. Kazam, and W. I. Kuhel, “Parathyroid localization with modified 4D-computed tomography and ultrasonography for patients with primary hyperparathyroidism,” The Laryngoscope, vol. 121, no. 6, pp. 1219–1224, 2011. View at: Publisher Site | Google Scholar
  59. L. I. Eichhorn-Wharry, A. M. Carlin, and G. B. Talpos, “Mild hypercalcemia: an indication to select 4-dimensional computed tomography scan for preoperative localization of parathyroid adenomas,” The American Journal of Surgery, vol. 201, no. 3, pp. 334–338, 2011. View at: Publisher Site | Google Scholar
  60. M. D. Beland, W. W. Mayo-Smith, D. J. Grand, J. T. Machan, and J. M. Monchik, “Dynamic MDCT for localization of occult parathyroid adenomas in 26 patients with primary hyperparathyroidism,” American Journal of Roentgenology, vol. 196, no. 1, pp. 61–65, 2011. View at: Publisher Site | Google Scholar
  61. C. C. Lubitz, G. J. Hunter, L. M. Hamberg et al., “Accuracy of 4-dimensional computed tomography in poorly localized patients with primary hyperparathyroidism,” Surgery, vol. 148, no. 6, pp. 1129–1138, 2010. View at: Publisher Site | Google Scholar
  62. M. M. Mortenson, D. B. Evans, J. E. Lee et al., “Parathyroid exploration in the reoperative neck: improved preoperative localization with 4D-computed tomography,” Journal of the American College of Surgeons, vol. 206, no. 5, pp. 888–895, 2008. View at: Publisher Site | Google Scholar
  63. S. E. Rodgers, G. J. Hunter, L. M. Hamberg et al., “Improved preoperative planning for directed parathyroidectomy with 4-dimensional computed tomography,” Surgery, vol. 140, no. 6, pp. 932–941, 2006. View at: Publisher Site | Google Scholar
  64. D. P. Frush, E. B. Spencer, L. F. Donnelly, J. Y. Zheng, D. M. DeLong, and G. S. Bisset, “Optimizing contrast-enhanced abdominal CT in infants and children using bolus tracking,” American Journal of Roentgenology, vol. 172, no. 4, pp. 1007–1013, 1999. View at: Publisher Site | Google Scholar
  65. M. Mazloumi, G. Van Gompel, V. Kersemans, J. de Mey, and N. Buls, “The presence of contrast agent increases organ radiation dose in contrast-enhanced CT,” European Radiology, vol. 30, 2021. View at: Google Scholar
  66. M. K. Gill, A. Vijayananthan, G. Kumar, K. Jayarani, K. H. Ng, and Z. Sun, “Use of 100 kV versus 120 kV in computed tomography pulmonary angiography in the detection of pulmonary embolism: effect on radiation dose and image quality,” Quantitative Imaging in Medicine and Surgery, vol. 5, no. 4, pp. 524–533, 2015. View at: Publisher Site | Google Scholar

Copyright © 2021 Steven Raeymaeckers et al. This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.