Security and Communication Networks / 2020 / Article / Tab 6

Research Article

Wearable Sensor-Based Human Activity Recognition Using Hybrid Deep Learning Techniques

Table 6

Accuracy of different batch size on test sets.

Batch sizeRecognition rate (%)

2591.74
5092.88
7592.92
10093.10
12594.33
15095.87
17593.45
20093.37
22593.72
25093.45
27592.84
30093.35
32594.06
35093.34
37592.96
40093.53