Research Article

Proposed Configurations for the Use of Smart Dampers with Bracings in Tall Buildings

Table 3

Buildings responses for both comfort and security reasons ( -direction).

CriteriaUncontrolledPassive-onDecentralized bang-bang
+0% Stiffness+0% Stiffness+10% Stiffness−10% Stiffness+0% Stiffness+10% Stiffness−10% Stiffness

= 10 yrsRMS Acc. (mg)13.02683.6350 (72.10%)3.47103.81383.1292 (75.98%)2.95823.3362
= 28 m/sPeak Acc. (mg)37.708716.1623 (57.14%)17.156018.416017.9946 (52.28%)16.119720.7541

Security,
= 100 yrs
= 34.4 m/s
RMS Disp. (m)0.34960.1046 (70.08%)0.09290.11600.1001 (71.37%)0.08970.1116
Peak Disp. (m)1.22900.5381 (56.22%)0.48540.56370.5203 (57.66%)0.49890.5649
RMS Drift (rad)0.00110.00057 (56.22%)0.000510.000630.00054 (71.58%)0.000480.00060
Peak Drift (rad)0.00660.0029 (56.06%)0.00270.00310.0029 (56.06%)0.00270.0030
RMS SL (N)1.347 × 1074.711 × 106 (65.03%)4.5212e64.8032e64.4153e6 (67.22%)4.2727e64.5132e6
Peak SL (N) 4.864 × 1072.784 × 107 (42.76%)2.9253e72.1284e72.5724e7 (47.11%)2.6732e72.0441e7
RMS BM (N.m)1.994 × 1096.5375e8 (67.21%)6.2312e86.6876e86.0546e8 (69.64%)5.8027e86.2344e8
Peak BM (N.m)6.873 × 1093.759 × 109 (45.31%)3.6794e92.9540e93.4835e9 (49.32%)3.6521e92.7948e9