Discussion on Application of Embedded Operating System in Dual-Core Smart Electric Meter
Table 3
Source address and destination address coding rules of protocol data frames.
bit7
bit6
bit5
bit4
bit3
bit2
bit1
bit0
Process number 0: initial value 1: basic APP 2: communication service 3: metering management service 4: platform management service 5: extended app1 6: extended app2 7: extended app3 8: expand app4 9: expand app5 10: expand app6 11: extend app7 12: extend app8 13: extend app9 14: extend app10 15: virtual bus service
Reserve
Every thread number in APP, 0–7 0: main thread Basic APP 0: general basic application app 1: time-sharing measurement 2: demand measurement 3: freezing 4: display 5: cost control 6: event Communication APP 1: uplink carrier 2: downlink Bluetooth 3: load identification 4: other communications (continuous coding) Other processes