Research Article

Biomechanical Evaluation of a Mandibular Spanning Plate Technique Compared to Standard Plating Techniques to Treat Mandibular Symphyseal Fractures

Table 3

Statistical analysis summary.

TestBetween groupsStatistical significance value

Peak loadControl versus 2PPYes0.004
Peak loadControl versus SP1No0.04
Peak loadControl versus LSNo0.09
Peak load2PP versus SP1Yes0.009
Peak load2PP versus LSYes0.009
Peak loadSP1 versus LSNo0.92
StiffnessControl versus 2PPYes0.004
StiffnessControl versus SP1No0.01
StiffnessControl versus LSNo0.01
Stiffness2PP versus SP1Yes0.009
Stiffness2PP versus LSYes0.009
StiffnessSP1 versus LSNo0.92

considered statistically significant.