Lundgren et al. [30] Random sequence generationRandomised but not describedUnclear risk of bias
Allocation concealmentRandomised but not describedUnclear risk of bias
Blinding of participants and personnelBlinding not possibleNot assessed
Incomplete outcome dataFollow-up data in each group incompleteModerate risk of bias
Selective reportingClear outcomesLow risk of bias
Other sources of biasNoneLow risk of bias

Creasy et al./Perkins et al. [19, 20] Random sequence generationRandomised but not describedUnclear risk of bias
Allocation concealmentRandomised but not describedUnclear risk of bias
Blinding of participants and personnelBlinding not possibleNot assessed
Incomplete outcome dataNo loss to follow-up reportedLow risk of bias
Selective reportingClear outcomesLow risk of bias
Other sources of biasNoneLow risk of bias

Gelin et al. [29] Random sequence generationRandomised via computer based algorithmLow risk of bias
Allocation concealmentRandomised via computer based systemLow risk of bias
Blinding of participants and personnelBlinding not possibleNot assessed
Incomplete outcome dataSome loss to follow-upModerate risk of bias
Selective reportingClear outcomesLow risk of bias
Other sources of biasNoneLow risk of bias

Hobbs et al. [21] Random sequence generationRandomised with 2 × 2 factorial designLow risk of bias
Allocation concealmentComputer generated randomisationLow risk of bias
Blinding of participants and personnelBlinding not possibleNot assessed
Incomplete outcome dataFour withdrawalsLow risk of bias
Selective reportingClear outcomesLow risk of bias
Other sources of biasNoneLow risk of bias

Badger et al. [31] Random sequence generationRandomised but not describedUnclear risk of bias
Allocation concealmentRandomised but not describedUnclear risk of bias
Blinding of participants and personnelBlinding not possibleNot assessed
Incomplete outcome dataAll patients lost to 6-month follow-upHigh risk of bias
Selective reportingClear outcomesLow risk of bias
Other sources of biasNoneLow risk of bias

Greenhalgh et al. [26] Random sequence generationDetailed description of Stata generated randomisationLow risk of bias
Allocation concealmentComputer generated randomisationLow risk of bias
Blinding of participants and personnelBlinding not possibleNot assessed
Incomplete outcome dataModerate loss to follow-upModerate risk of bias
Selective reportingClear outcomesLow risk of bias
Other sources of biasNoneLow risk of bias

Kruidenier et al. [27] Random sequence generationComputer generated block randomisationLow risk of bias
Allocation concealmentComputer generated block randomisationLow risk of bias
Blinding of participants and personnelNo blindingHigh risk of bias
Incomplete outcome dataModerate losses to follow-upModerate risk of bias
Selective reportingClear outcomesLow risk of bias
Other sources of biasNoneLow risk of bias

Mazari et al. [25] Random sequence generationSealed envelope used to randomiseLow risk of bias
Allocation concealmentSealed envelope used to randomiseLow risk of bias
Blinding of participants and personnelBlinding not describedUnclear risk of bias
Incomplete outcome dataModerate loss to follow-upModerate risk of bias
Selective reportingClear outcomesLow risk of bias
Other sources of biasNoneLow risk of bias

Spronk et al./Fakhry et al. [2224] Random sequence generationComputer generated block randomisationLow risk of bias
Allocation concealmentComputer generated block randomisationLow risk of bias
Blinding of participants and personnelBlinding not possibleNot assessed
Incomplete outcome dataProlonged study with some loss to follow-upModerate risk of bias
Selective reportingClear outcomesLow risk of bias
Other sources of biasNoneLow risk of bias

Murphy et al. [18, 32] Random sequence generationWeb based randomisationLow risk of bias
Allocation concealmentWeb based randomisationLow risk of bias
Blinding of participants and personnelObservers blindedLow risk of bias
Incomplete outcome dataProlonged study with some loss to follow-upModerate risk of bias
Selective reportingClear outcomesLow risk of bias
Other sources of biasNoneLow risk of bias

Bø et al. [28] Random sequence generationComputer based randomisationLow risk of bias
Allocation concealmentComputer based randomisationLow risk of bias
Blinding of participants and personnelObservers blindedLow risk of bias
Incomplete outcome dataNo loss to follow-upLow risk of bias
Selective reportingClear outcomesLow risk of bias