Review Article
Dynamic Analysis of Coolant Channel and Its Internals of Indian 540 MWe PHWR Reactor
Table 2
Natural frequencies of coolant channel for fault scenarios.
| Case | Frequency (Hz) | 1st mode | 2nd mode | 3rd mode |
| Case 1 (design) | 6.45 | 17.62 | 32.66 | Case 2 | 6.42 | 17.05 | 30.05 | Case 3 | 6.36 | 16.64 | 27.12 | Case 4 | 6.41 | 17.59 | 25.65 | Case 5 | 6.25 | 15.69 | 27.11 | Case 6 | 4.99 | 13.55 | 27.30 | Case 7 | 5.52 | 16.67 | 25.82 | Case 8 | 4.02 | 17.53 | 31.92 | Case 9 | 2.69 | 13.77 | 22.73 | Case 10 | 2.66 | 13.55 | 26.43 | Case 11 | 6.26 | 16.15 | 26.74 | Case 12 | 6.41 | 17.59 | 29.71 |
|
|