Review Article
International Standard Problems and Small Break Loss-of-Coolant Accident (SBLOCA)
Table 9
General code deficiencies for the considered ISPs.
| ISP no. | Identification no. of Deficiency | Code deficiencies |
| 18 | (1) | Break flow | (2) | Stratification in cold and hot leg | (3) | Mass distribution in primary side | (4) | Mixing in the downcomer |
| 20 | (5) | Steam condensation | (6) | Level simulation in secondary side |
| 22 | (6) | Unability to predict mass inventory in secondary side | (7) | Heat transfer between EFW and hot SG walls | (8) | Pressurizer behaviour including PORV leak | (9) | Coolant mass distribution in primary circuit | (1) | Break flow | (2) | Stratification in cold and hot leg |
| 26 | (10) | CCFL in SG plena | (3–11) | Core level depression | (12) | Core uncovery and heat-up |
| 27 | (1) | Break flow | (2) | Stratification in cold and hot leg | (3) | Mass distribution in primary side | (4) | Mixing in the downcomer | (12) | Core uncovery and heat-up | (13) | Low pressure period |
|
|