Research Article

CATHARE Multi-1D Modeling of Coolant Mixing in VVER-1000 for RIA Analysis

Table 1

Initial state.

ParameterPlant dataCathare 12 sectorsCathare 16 sectorsCathare 24 sectorsUncertainty

Core power, MW281281281281± 60
Pressure above the core, MPa15.5915.60815.60515.605± 0.3
Cold leg no. 1 coolant temp, K541.75541.75 (BC)541.75 (BC)541.75 (BC)± 1.5
Cold leg no. 2 coolant temp, K541.85541.85 (BC)541.85 (BC)541.85 (BC)± 1.5
Cold leg no. 3 coolant temp, K541.75541.75 (BC)541.75 (BC)541.75 (BC)± 1.5
Cold leg no. 4 coolant temp, K541.75541.75 (BC)541.75 (BC)541.75 (BC)± 1.5
Mass flow rate 1, kg/s4737473747374737± 200
Mass flow rate 2, kg/s47184717.947184718± 200
Mass flow rate 3, kg/s4682468246824682± 200
Mass flow rate 4, kg/s483448344833.84833.9± 200
Reactor mass flow rate, kg/s18971189711897118971± 800
Hot leg no. 1 coolant temp, K545544.76544.66544.65± 1.5
Hot leg no. 2 coolant temp, K545.9544.70544.68544.68± 1.5
Hot leg no. 3 coolant temp, K544.9544.71544.70544.71± 1.5
Hot leg no. 4 coolant temp, K545544.84544.84544.83± 1.5
Reactor pressure drop, MPa0.4180.4170.4180.418± 0.043