Review Article
Modelling of Heat Transfer Phenomena for Vertical and Horizontal Configurations of In-Pool Condensers and Comparison with Experimental Findings
Table 1
IC data, taken as reference for the calculations.
| Parameter | Choice |
| Tube outer diameter | 50.8 mm | Tube inner diameter | 46.2 mm | Tube thickness | 2.3 mm | Thermal conductivity | 17.4 W/mK | Pressure | 72.4 bar | Fouling | K/W | Plugging | 5% of tubes | Thermal power | 35 MW | Number of tubes | 240 (2 units of IC) | Flowrate per tube | 0.103 kg/s | Mass flux G | 61.47 kg/s |
|
|