Research Article
Experimental Characterization of a Passive Emergency Heat Removal System for a GenIII Reactor
Table 2
Test matrix on IES loop.
| Filling Ratio (FR) | Test section electrical power (kW) | Heat losses compensation | Noncondensable gas presence |
| 0.18 | 13 | yes | no | 23 | yes | 33 | yes | 0.31 | 23 | yes | no | 33 | yes | 43 | yes | 0.49 | 23 | yes | yes | 33 | yes | 43 | yes | 0.61 | 23 | yes | no | 33 | yes | 43 | yes | 0.79 | 23 | yes | no | 33 | yes | 43 | no |
|
|