Test matrix on IES loop.

Filling Ratio (FR)Test section electrical power (kW)Heat losses compensationNoncondensable gas presence

0.1813yesno
23yes
33yes
0.3123yesno
33yes
43yes
0.4923yesyes
33yes
43yes
0.6123yesno
33yes
43yes
0.7923yesno
33yes