SPES3 Facility RELAP5 Sensitivity Analyses on the Containment System for Design Review

Table 2

Characteristics of the IRIS cases.

IRIS casesCharacteristicsResults

IRIS-HT1Containment heat structures simulated only for the DW.Starting point for comparison with SPES3.

IRIS-HT5gHeat structures added to all containment compartments and secondary sidepiping.
PSS main vent pipe connection to DW rise of 4 m.
PSS sparger set at 0.75 m from PSS bottom.
RWST remodelled with parallel slice approach.
Similar containment pressure response with SPES3.

IRIS-HT6_rwstcSG tubes inner layer removed which simulated the Fouling.
ADS stage II actuation signal corrected to intervene on low LGMS mass.
RWST remodelling according to PERSEO area ratio and HTC calibration on experimental data. EHRS heat transfer parameters set as in SPES3 (by multiplier fouling factors) [12, 13].
RWST top pipe introduction for connection to atmosphere.
Correction of energy transfer parameters at the GOTHIC and RELAP5 code couplings.
Better matching of EHRS long-term energy transfer to RWST.

IRIS-HT6_rwstc1aCorrected elevation difference between the RELAP5 and GOTHIC parts of the model: the ADS stage I vent pipe end should be 0.5 m from QT bottom (it was connected to QT top); LGMS tanks rise of 0.75 m.Results very similar to IRIS-HT6_rwstc
BASE CASE for FSA final application.