Research Article

Experimental Studies for the VVER-440/213 Bubble Condenser System for Kola NPP at the Integral Test Facility BC V-213

Table 3

Test plan.

Test designation (according to [5])AccidentTest purpose

Test 1LB LOCAIntegral behavior of the compartment and bubble condenser system
Test 4LB LOCAResponse of bubble condenser system to maximum steam loading
Test 5LB LOCAResponse of bubble condenser system to maximum air loading
Test 7MSLBResponse of bubble condenser system to maximum air loading
Test 9MSLBResponse of bubble condenser system to maximum steam loading
Test 12SB LOCAObservation of condensation oscillations