Science and Technology of Nuclear Installations / 2012 / Article / Tab 1

Research Article

Trace Code Validation for BWR Spray Cooling Injection and CCFL Condition Based on GÖTA Facility Experiments

Table 1

Test number 78 initial parameters.

ParameterNominalActual

Initial bundle power (kW)300303
Spray flow rate in the bundle (kg/s)0.120.12
Fraction of the spray flow rate in the bypass (kg/s)20%20%
Pressure (MPa)0.10.11
Initial peak cladding temperature (°C)700736
Spray water temperature (°C)6060
Steam ventingTopTop

Article of the Year Award: Outstanding research contributions of 2020, as selected by our Chief Editors. Read the winning articles.