Science and Technology of Nuclear Installations / 2012 / Article / Tab 1

Research Article

Trace Code Validation for BWR Spray Cooling Injection and CCFL Condition Based on GÖTA Facility Experiments

Table 1

Test number 78 initial parameters.

ParameterNominalActual

Initial bundle power (kW)300303
Spray flow rate in the bundle (kg/s)0.120.12
Fraction of the spray flow rate in the bypass (kg/s)20%20%
Pressure (MPa)0.10.11
Initial peak cladding temperature (°C)700736
Spray water temperature (°C)6060
Steam ventingTopTop

We are committed to sharing findings related to COVID-19 as quickly as possible. We will be providing unlimited waivers of publication charges for accepted research articles as well as case reports and case series related to COVID-19. Review articles are excluded from this waiver policy. Sign up here as a reviewer to help fast-track new submissions.