Consistent Posttest Calculations for LOCA Scenarios in LOBI Integral Facility
Table 3
Resulting sequence of events, comparison between experimental test and calculated results of BL-44.
| Events/set-points | Time after experiment initiation (s) | Calculated time after transient initiation (s) |
| Break opening | 0.0 | 0.0 | Scram power curve enabled | 1.4 | 2.6 | Start of the main coolant pumps coast down | 0.9 | 0.0 | Main steam line valve closure | — | 3.6 | Feedwater valve closure | 1.3 | 2.6 | Upper plenum in saturation condition | 10.0 | 13.0 | Pressurizer emptied | 25.0 | 25.0 | Break two-phase flow | 117.0 | 115.0 | First dry out | 189.0 | — | Loop seal clearing—intact loop | 197.0 | 2250.0 | Loop seal clearing—broken loop | — | 250.0 | Occurrence of minimum primary side mass | | | First | 427.0 | 445.0 | Second | 2071.0 | 2070.0 | Primary-secondary pressure reversal | 208.0 | 212.0 | Second dry out | 372.0 | 420.0 | Accumulator injection starts | 429.0 | 439.0 | Accumulator injection stops | 970.0 | 1065.0 | Rewetting due to accumulator | 547.0 | 525.0 | Final dry out | 1711.0 | 1795.0 | LPIS start | 2065.0 | 2073.0 | Final rewetting | 2203.0 | 2207.0 | End of the test | 2400.0 | 3000.0 |
|
|