Abstract

Results of the CATHARE code calculations related to asymmetric cooldown tests in the PKL facility are presented. The test under consideration is the G2.1 experiment performed within the OECD/NEA PKL-2 project. It consists of carrying out a cooldown under natural circulation conditions in presence of two (out of four) emptied Steam Generators (SGs) and isolated on their secondary sides. The main goal of the current study is to assess the impact of a chosen cooldown strategy upon the occurrence of a Natural Circulation Interruption (NCI) in the inactive (i.e., noncooling) loops. For this purpose, three G2.1 test runs were investigated. The calculation results emphasize, mainly, the effect of the cooldown strategy, and the conditions that could lead to the occurrence of the NCI phenomenon.

1. Introduction

After the reactor trip, several cooldown procedures can be followed in order to bring the primary side temperature and pressure to the Residual Heat Removal System (RHRS) operating conditions. For example, the primary cooldown can be carried out by a linear or stepwise temperature decrease, with a coincident or delayed depressurization. Generally, the Emergency Response Guidelines (ERG) impose a limit on the cooldown rate in order to prevent steam bubble formation under the reactor vessel head during the depressurization phase. Furthermore, Natural Circulation Interruption (NCI) has also to be avoided during the cooldown phase as pointed out by [1]. Indeed, the interruption of natural circulation in one or more inactive primary loops could stop the cooldown in these loops and lead to degradated states [1, 2].

Up to now, the NCI phenomenon has not yet been deeply investigated analytically and experimentally as well. The issue was addressed by the OECD/NEA PKL-2 project [3] in order to assess the impact of different cooldown strategies on the occurrence of the flow stagnation in the inactive loops where the corresponding SGs are emptied and isolated. Former studies, on the PKL facility, made by Dubiel and Mandl [4] showed that NCI could occur in the loop with isolated and filled SGs if a (stepwise) cooldown at 50°C/h, with a mean value around 10°C/h, is performed. Recently, Vlassenbroeck et al. [1] investigated the NCI in a typical 2-loop NPP using a thermal-hydraulic system code. The latter study emphasised the fact that a linear cooldown rate larger than 14°C/h could lead to NCI.

In the current study, three experimental runs performed in the 4-loop PKL facility are considered. They concern three cooldown strategies under natural circulation conditions where 2 out of 4 SG are emptied and isolated on their secondary sides. The objective was to check if natural circulation is maintained in all loops at a continuous cooldown rate of 50°C/h and if not, whether natural circulation can be maintained by a stepwise cooldown rate at 50°C/h.

The test simulation was carried out using the advanced thermal-hydraulic system code CATHARE 2/V2.5_1/mod8.1 developed by CEA, EDF, AREVA, and IRSN [5]. The current study allows drawing conclusions about the NCI occurrences under some specific conditions and also about the capabilities of the current computational tools in predicting the NCI phenomenon, to better understand the interaction between the key parameters expected during the transient.

2. PKL Facility Description

The PKL (Primaer KreisLauf) facility [6] has been built in order to perform experimental investigations related to different integral behaviour of a typical 4-loop 1300-MW Siemens pressurized water reactor (PWR) plant under normal and accident conditions. The layout of the PKL facility (Figure 1) shows the primary side and the most significant components of the secondary side. The scaling ratios of the facility are elevation ratio and for the power, volumes, and the cross section areas. However, the maximum operating primary pressure is 45 bar.

The primary side is represented by 4 identical and symmetric loops arranged around the reactor pressure vessel. For each loop, a secondary side is associated, as well as all the significant interface and auxiliary systems.

3. CATHARE Model for PKL

The adopted CATHARE nodalization for the current study is a full 1D model. In total, the nodalization contains almost thousand of hydraulic nodes and heat structures distributed on the primary and the secondary side.

3.1. PKL Reactor Vessel

The PKL vessel model as modelled by the CATHARE code is composed by the upper downcomer ring (VIN), the 2 downcomer pipes (VDC1 & VDC2), the lower plenum (VLP), the heated core zone (VCO) and the core bypass (VCB) zone, the upper plenum (VUP), the upper head (VUH), and the upper head bypass (VHB). In Figure 2, the aforementioned components are shown, more details are provided in Table 1.

The downcomer consists of an upper downcomer ring where the flows coming from the different cooling loops are mixed up. The descending part of the downcomer consists of 2 pipes connecting the downcomer ring to the core lower plenum. The rod bundle consists of 314 uniformly disposed heated rods. The latter were lumped into one equivalent heating channel with a uniform axially distributed power. The CATHARE nodalization was chosen to fit the spacer’s position. The geometry of the core upper plenum includes the connections to the 4 hot legs and the lower part of the upper head. The upper head is connected to the core upper plenum through 9 holes that simulate the guided tubes zone, and also to the upper part of the downcomer through 4 upper head bypass pipes.

3.2. Steam Generators (Primary Side)

The SG zone is composed of an inlet zone, SG U-tubes, and an outlet zone. The total number of U-tubes in each SG is 28, distributed in 7 elevations having 4 tubes each (see Figure 3(a)). In the CATHARE model, for each elevation, the 4 tubes are lumped into one representative tube as shown in Figure 3(b). Each lumped tube is divided into 36 nodes in order to get a detailed representation of the heat transfer between the primary and secondary side.

3.3. Secondary Circuit Description and Modelling

The main components of the secondary circuit are summarized in Table 2. The CATHARE model of the secondary circuit is shown in Figure 4, in which the upper annular downcomer of the steam generator is represented by a VOLUME component. The latter is connected to the feedwater line, the two downcomer pipes, and the recirculation line (the carry-under of the steam separator of the SG). The downcomer is represented by one AXIAL component that lumps the 2 real pipes. The riser nodalization is chosen to cope with the primary side nodalization of the U-tubes in order to satisfy the CATHARE code rules concerning the heat exchange between the primary and secondary sides. The steam dome volume is modelled by the VOLUME component. The dryer or the separator option was not activated since in the real PKL configuration no special features exist for the phase separation.

3.4. Nodalization Assessment

The single-phase pressure losses of the PKL facility correspond to a large extent to the values encountered in a PWR. Under steady-state conditions, the pressure drop across the primary side was checked against measured data provided in [7], taking into account the butterfly valve (located downstream of each primary coolant pump) pressure drops that simulate the frictions of the locked rotor of the primary pumps. On the other hand, the heat losses of the main primary components were also tuned in the CATHARE model in order to match the measured heat losses as documented in [8]. It should also be mentioned that some unknown cross section of some loop components were tuned in order to match the measured volumes as reported in [9].

The assessment of the nodalization is therefore carried out through a comparative study between the measured and calculated steady-state PKL operating conditions. This study is detailed in the following sections, and the main key parameters are outlined in Tables 6 and 7.

4. G2.1 Test Description

The PKL-2 G2.1 test consists of 3 runs in which 3 different cooldown procedures are followed. They concern three cooldown strategies under natural circulation conditions where 2 out of 4 SG are emptied and isolated on their secondary sides. The objective is to check if natural circulation is maintained in all loops at a continuous cooldown rate of 50°C/h and if not, whether natural circulation can be maintained by a stepwise cooldown rate at 50°C/h.

In Run-1 and Run-2, a continuous cooldown with different way of decreasing the primary pressure is carried out, while for Run-3 a stepwise cooldown procedure is performed.

4.1. NCI Phenomenon

NCI can occur under single- or two-phase flows due to several initiating events. Under two-phase flow, NCI can result from a loss of primary mass inventory as in the case of a small SBLOCA, or when a steam bubble is formed in the SG U-tubes.

On the other hand, during single-phase flow, NCI can occur progressively as the heat sink, in a loop, is gradually lost. The process is generally slow and can be described by the following single-phase momentum static governing set (1) under natural circulation conditions and negligible acceleration losses: with .

Indeed, when the heat sink is lost in loop 1 for instance, the second term of the left-hand side of (1) becomes null. Therefore, the flow in the inactive loop will decrease gradually and may stop when the driving force in the reactor pressure vessel minus the friction in the vessel are counterbalanced by the driving force in the inactive loop

4.2. Conditioning Phase

During the G2.1 test, the rod bundle power was fixed at 642 kW in which 100 kW was added to compensate the heat losses in the loops. This power level corresponds to a scaled decay heat power of 1.7%.

The initial conditions of each of the individual test runs were adjusted through the so-called conditioning phases during which the secondary sides of SG-1 and SG-3 were emptied and isolated afterwards. The main test phase starts when the temperature level of the secondary side of the isolated SGs reaches the primary side temperature.

4.3. Test Phase

For Run-1, the test consists in carrying out a continuous cooldown at 50°C/h and primary depressurization by spraying in the pressurizer. The pressure decrease is controlled in order to ensure a subcooled margin at the core outlet. The main events for Run-1 are outlined in Table 3. It should be mentioned here that only for Run-1 a heat-up phase of 360 s was performed.

For Run-2, the test consists in carrying out a continuous cooldown rate of 50°C/h but with controlled primary depressurization that ensures subcooling in the apex of the SG U-tubes. The main events for Run-2 are outlined in Table 4.

And finally for Run-3, a stepwise cooldown, during which subcooling in the SG U-tubes is maintained, is performed. The primary temperature is decreased successively after a short stabilization time by 20°C, 30°C, and 40°C following a cooldown rate of 50°C/h. The main events for Run-3 are outlined in Table 5.

5. Calculation and Experimental Results

The simulation of each run covers the conditioning and the test phases. The results at the end of the conditioning phase are summarized in Tables 6 and 7 for the primary and secondary side, respectively. On the whole, good agreement between the calculation and the experimental results is obtained. This constitutes a good qualitative indicator for the representativeness of the developed CATHARE model for PKL as well.

5.1. G2.1 Run-1

The first run starts with the isolation of the secondary side of the active SG-2 and SG-4 from the steam header. A heat-up period in the primary side follows during 360 s approximately. The cooldown through the discharge valves begins afterwards.

At the beginning of the cooldown phase, as illustrated in Figure 5, the calculated hot-leg temperature in the active loops is overestimated by 2.0°C. On the other hand, as illustrated in Figure 6, the flow in the active loops is underestimated by about 10%, and overestimated by 20% in the inactive loops. This observation can be explained by the difference between the calculations and the measurements at the end of the conditioning phase. As can be seen in Figure 7, the heat sink in the experiment is almost lost, while it is not the case in the calculation results. This is more probably due to an underestimated calculated value of the secondary pressure. On the whole, at the beginning of the cooldown phase, the total primary flow agrees rather well with the experimental one.

Through the cooldown phase, the experimental and the calculated coolant temperature evolutions in loop-2 and loop-4 follow well the linear 50°C/h rate. This cooldown rate is obtained by controlling the atmospheric dump valve (ADV) opening on both steam lines, calculated as reported in Figure 8. The subsequent secondary pressure decreases are shown in Figure 9. The agreement between the calculations and the measurement is less good in this case.

In Figure 6, the flow rate evolutions in loop-2 and loop-4 agree well with the experimental trends but the agreement is less good in the inactive loops. In fact, differences exist between the measured flow rates in loop-1 and loop-3 and become more pronounced later on. Indeed, the flow interrupts first in loop-1, at around 5300 s, and later in loop-3 after 1500 s. This difference could be explained by the fact that loop-1 and loop-3 may have different pressure and heat losses. This is not the case in the CATHARE PKL model; the inactive loops are modelled identically and thus the calculated flow rates are the same, as well as the predicted flow interruption time occurrence (at about 7000 s). It should however be noted that the NCI in Run-1 is the consequence of steam formation in the U-tubes, due to continuous depressurization of the primary side.

According to the experimental and calculation results, the flow interruption process follows in some manner a chaotic trend. It does not start in the longest tube and end in the shortest one, as it could be expected. As can be seen in Figure 10(a), the flow for loop-1 is first interrupted in the middle tube (Tube-19), then in the longest tube (Tube-29), and finally in the shortest tube (Tube-1). While for loop-3 (see Figure 10(b)), the flow stops first in the longest tube (Tube-29), then in the shortest tube (Tube-2) and later in the middle tube (Tube-19). This behaviour is obviously governed by the void growth, the temperature and flow redistribution in the U-tubes.

This trend is also observed in the CATHARE predictions (see Figure 11), where the flow is interrupted first in the middle length tube, then in the longest tube, and finally, in the shortest tube.

5.2. G2.1 Run-2

The second run is more or less identical to the first one, except for the fact that the primary pressure is kept high enough to preclude any void formation in the U-tubes. Unlike the case in Run-1, the NCI is the result of the driving force balance in the different loops of the tests facility. The test starts by the isolation of the secondary side of the active SG from the steam header. The cooldown via the corresponding ADV is activated immediately at the end of the conditioning phase; there is no heat-up period in this run.

At the beginning of the cooldown phase, as can be seen in Figure 12, the calculated hot leg temperature in the active loops is overpredicted by 2.0°C. This difference was already observed in Run-1 case. On the other hand, unlike the first run, the coolant flow in all loops is well predicted (see Figure 13); the final state of the conditioning phase of Run-2 is well simulated.

Throughout the cooldown phase, the calculated coolant temperatures (see Figure 12), the flow rate evolutions (see Figure 14), and the secondary pressure decrease (see Figure 13), in the active loop-2 and loop-4, match well the experimental trends. As it was the case for Run-1, the agreement is less good in the inactive loop-1 and loop-3. Indeed, there are differences between the measured flow rates in loop-1 and loop-3. This leads to a flow interruption in loop-1, and a flow restart in loop-3 at around 5500 s. This flow restart, as can be seen in Figure 12, is most probably due to the fact that at the end of the test (beyond 5000 s) the cooldown rate of 50°C/h can no longer be ensured. Its mean value, after 5000 s, is less than 25°C/h.

In the CATHARE model, the flow interrupts in both loops at the same time as a consequence of the driving forces balances in loop-1 and loop-3 and the driving force in the vessel. The code predicts an NCI time that corresponds with the experimental NCI observed in loop-1.

5.3. G2.1 Run-3

During the third run, a stepwise cooldown procedure is performed. As in Run-2, the primary pressure is kept high enough to preclude any void formation in the U-tubes. In the first step, the active loops temperature is decreased by 20°C following a linear cooldown rate of 50°C/h. After a stabilization period of 1800 s, the active loop temperature is reduced by 30°C according to a cooldown rate of 50°C/h. Then, after stabilization period of 2260 s, the third and last step is initiated. The temperature is decreased by 40°C during 7120 s instead of 2880 s. Indeed, during this step the cooldown rate of 50°C/h could not be reached at the end of the test due to the fact that the secondary side pressure is almost at atmospheric levels.

As shown in Figure 15, the calculated cold and hot-leg temperatures in the active loops are well predicted. The coolant flow in all loops is also well predicted (see Figure 16). This trend is kept throughout the entire test time span. The secondary pressure decrease is also well predicted by the calculation (see Figure 17). As it is the case for the former runs, the agreement between the calculated and measured mass flow rate in the inactive loops is less good. This is mainly due to the differences in the measured flow rates that exist between loop-1 and loop-3. This difference is most probably due to geometric differences between loop-1 and loop-3, and also to some mixing effect in the upper part of the downcomer that are not modelled in the CATHARE model. However, the predicted values lie between the measured mass flow rates in loop-1 and loop-3.

Unlike Run-1 and Run-2, no flow interruption in the inactive loops is observed experimentally for Run-3. The flow rate in these loops decrease with decreasing temperatures of the active loops. In loop-1, the flow rate reaches 15% of its initial value during the third cooldown step. However, as already mentioned above, the cooldown rate of 50°C/h during the third step was not ensured; the mean cooldown rate during the last step is around 36°C/h. Therefore, if during this period the cooldown rate of 50°C/h would have been ensured, the flow rate in loop-1 would probably have been interrupted. Furthermore, if shorter periods between the temperatures decrease of the stepwise cooldown procedure were considered, NCI would also occur.

6. Conclusions

In the current study, asymmetric cooldown tests with empty and isolated SGs in the 4-loop PKL facility are investigated. The impacts of several cooldown strategies on the NCI occurrence are assessed experimentally and simulated numerically with the CATHARE code. According to the calculation results, it can be concluded that:(i)NCI occurs when high linear value of the cooldown rate (i.e., 50°C/h) is performed. The NCI occurs in Run-1 and Run-2 due to steam formation in the apex of the U-tubes, and due to driving forces balance in the loops, respectively;(ii)a stepwise cooldown procedure allows avoiding NCI, as far as the temperature steps are rigorously chosen in relation to the decay heat level and the time interval between successive cooldown steps; (iii)the experiments show that slight configuration differences between inactive loops could have an important impact on the NCI occurrence;(iv)the CATHARE computer code can accurately simulate the NCI phenomenon. However, deeper investigation and assessment of broader conditions could impact the NCI occurrence, as the power level, the cooldown rate and strategy, and the 3D mixing effect in the vessel downcomer.

Nomenclature

Friction pressure drop (N/m2)
:Density of the fluid (kg/m3)
G:Acceleration due to gravity (9.81 m/s2)
z:Vertical coordinate (m).

Acronyms

ADV:Atmospheric discharge valve
NC(I):Natural circulation (interruption)
NPP:Nuclear power plant
PRZ:Pressurizer
PWR:Pressurized water reactor
RCS:Reactor coolant system
RHRS:Residual heat removal system
SG:Steam generator.