Research Article

CATHARE Assessment of Natural Circulation in the PKL Test Facility during Asymmetric Cooldown Transients

Table 5

Main events for PKL2 G2.1 Run-3.

Time [s]Measures/Events

0Start of Run-3. Cooldown step-1 initiated: 50°C/h cooldown gradient by SG-2 and SG-4; temperature decrease by 20°C
90PRZ heater switched off
1460Cooldown step-1 finished
3270Cooldown step-2 initiated: 50°C/h cooldown gradient by SG-2 and SG-4; temperature decrease by 30°C
5490Cooldown step-2 finished
7750Cooldown step-3 initiated: 50°C/h cooldown gradient by SG-2 and SG-4; temperature decrease by 40°C
14870Cooldown step-3 finished
17520End of Run-3