Research Article
The Effective Convectivity Model for Simulation of Molten Metal Layer Heat Transfer in a Boiling Water Reactor Lower Head
Table 2
MELAD A1 experiment [
8] versus ECM prediction energy splitting and temperature.
| Methods | MELAD A1 | ECM |
| Input power (kW/m2) | 24.7 (+2%) | 24.7 | Top plate power output (kW/m2) | 21.7 | 20.6 | Side plate power output (kW/m2) | 17.5 | 19.5 | Bottom plate temperature (°C) | 59.1 | 57.2 | Average temperature of the top and bottom plates (°C) | 33.9 | 32.9 | Bulk temperature (°C) | 37.5 | 31.5 |
|
|