Research Article
Uncertainty and Sensitivity Studies with TRACE-SUSA and TRACE-DAKOTA by Means of Steady State BFBT Data
Table 4
Sensitivity coefficients for the single-phase flow pressure drop.
| Case (P700x) | Outlet pressure | Mass flow rate | Inlet temperature | Wall roughness | -spacer | Hydraulic diameter |
| 02 | 0.143 | 0.281 | −0.240 | −0.106 | 0.539 | −0.749 | 0.030 | 0.550 | 0.045 | 0.076 | 0.836 | — | 07 | 0.152 | 0.283 | −0.229 | −0.131 | 0.570 | −0.747 | 0.007 | 0.506 | 0.003 | −0.008 | 0.859 | — | 13 | 0.138 | 0.287 | −0.184 | −0.081 | 0.585 | −0.754 | 0.045 | 0.636 | −0.113 | −0.029 | 0.764 | — | 16 | 0.150 | 0.285 | −0.174 | −0.093 | 0.603 | −0.751 | 0.044 | 0.851 | −0.200 | −0.022 | 0.476 | — | 30 | 0.154 | 0.284 | −0.135 | −0.108 | 0.614 | −0.749 | −0.022 | 0.510 | −0.062 | 0.024 | 0.849 | — | 35 | 0.152 | 0.282 | −0.129 | −0.112 | 0.624 | −0.747 | 0.434 | 0.393 | −0.240 | −0.001 | 0.645 | — |
|
|