Research Article

Uncertainty and Sensitivity Studies with TRACE-SUSA and TRACE-DAKOTA by Means of Steady State BFBT Data

Table 7

Input parameter combinations and uncertainty results for the void fraction cases.

Case (4101-)Poutlet (bar)MFR (t/h)hsub (kJ/kg) (MW)Exp. (Pa)Mean (−)Max (−)Min (−)SD (−)Error (%)

049.7310.243.90.820.8400.8430.8470.8380.0020.31
0.8420.8460.8380.0020.25
1839.1910.1451.51.000.7550.7780.7850.7700.0032.98
0.7790.7850.7700.0033.14
2939.1754.6850.33.920.7570.7660.7730.7580.0041.17
0.7650.7740.7570.0041.11
4771.3229.9450.61.430.5360.5730.5940.5510.0106.97
0.5730.5990.5520.0106.97
6471.5969.5353.61.570.2630.2540.3270.1810.0333.38
0.2540.3120.1860.0333.38
8286.3554.5452.91.850.3760.4160.4560.3750.01810.54
0.4150.4500.3770.02010.31