Research Article
Uncertainty and Sensitivity Studies with TRACE-SUSA and TRACE-DAKOTA by Means of Steady State BFBT Data
Table 7
Input parameter combinations and uncertainty results for the void fraction cases.
| Case (4101-) | Poutlet (bar) | MFR (t/h) | hsub (kJ/kg) | (MW) | Exp. (Pa) | Mean (−) | Max (−) | Min (−) | SD (−) | Error (%) |
| 04 | 9.73 | 10.2 | 43.9 | 0.82 | 0.840 | 0.843 | 0.847 | 0.838 | 0.002 | 0.31 | 0.842 | 0.846 | 0.838 | 0.002 | 0.25 | 18 | 39.19 | 10.14 | 51.5 | 1.00 | 0.755 | 0.778 | 0.785 | 0.770 | 0.003 | 2.98 | 0.779 | 0.785 | 0.770 | 0.003 | 3.14 | 29 | 39.17 | 54.68 | 50.3 | 3.92 | 0.757 | 0.766 | 0.773 | 0.758 | 0.004 | 1.17 | 0.765 | 0.774 | 0.757 | 0.004 | 1.11 | 47 | 71.32 | 29.94 | 50.6 | 1.43 | 0.536 | 0.573 | 0.594 | 0.551 | 0.010 | 6.97 | 0.573 | 0.599 | 0.552 | 0.010 | 6.97 | 64 | 71.59 | 69.53 | 53.6 | 1.57 | 0.263 | 0.254 | 0.327 | 0.181 | 0.033 | 3.38 | 0.254 | 0.312 | 0.186 | 0.033 | 3.38 | 82 | 86.35 | 54.54 | 52.9 | 1.85 | 0.376 | 0.416 | 0.456 | 0.375 | 0.018 | 10.54 | 0.415 | 0.450 | 0.377 | 0.020 | 10.31 |
|
|