Research Article
CFD for Subcooled Flow Boiling: Parametric Variations
Table 4
Adapted parameters for different test series.
| Tests | | Equation (7) and Figure 3 | Equation (8) and Figure 4 | | | | | | |
| P26-G2-Q74-Txx | 28, 26, 20, 18, 16 | 0.24 | 45 | | 10 | 0.03125 | 0.5 |
| | 28, | | | | | 0.015 | 1.0 | P26-G3-Q118-Txx | 24, | 0.155 | 31 | | 10 | 0.015 | 1.0 | | 20, | | | | | 0.03125 | 1.0 | | 16 | | | | | 0.03125 | 0.5 |
| P26-G3-Q129-T28 | | | | | | 0.0075 | 1.0 | Q139, | 28 | 0.155 | 31 | | 10 | 0.0075 | 1.0 | Q148 | | | | | | 0.0 | 1.0 |
|
|