Main events of LSTF Test 3.

Event Experimental data (s)UPC LSTF 1D nodalization (s)UPC LSTF pseudo-3D nodalization (s)

High-pressure transient phase
 Break 000
 SCRAM signal25 33 33
  Turbine trip and closure MSIV
  PZR heater off
  Termination main feedwater
 Initiation of coastdown of primary coolant pumps 31 39 39
 Termination of continuous opening of SG relief valves, 
 termination of two-phase natural circulation, and break flow from single-phase liquid to two-phase flow
600 1238 1185
 Core liquid level starts to decrease (core uncovered)1545 14601475
 End high-pressure transient phase (PCT > 750 K) 1840 1852 1778
Conditioning phase
 HPI system activated 1850 1862 1788
 Break valve closed216321692161
 HPI system closed285228522852
 SG depressurization288028922880
 Termination of SG depressurization302430083012
 End of Conditioning phase (break valve reopening)332333233323
Low-pressure transient phase
 Break valve reopening 332333233323
 Primary pressure lower than SG secondary pressure 4108 4085 4105
 SG depressurization (CET > 623 K)4392 4297 4388
 Initiation of accumulator system (primary pressure = 2.6 Mpa) 4505 4419 4488
 Initiation of LPI system (primary pressure = 1.0 Mpa) 5005 4660 4741
 End of the transient 5500 5500 5500