Research Article

Experimental Research on Passive Residual Heat Removal System of Chinese Advanced PWR

Table 2

Effect of the hydraulic resistance.

NumberHydraulic resistance (m)TestCalculation
Natural circulation flow rate (kg/h)Power (kW)Natural circulation flow rate (kg/h)Power (kW)

186215.689.422792.7
2122211.088.522191.9
3153210.188.222092.7
4157209.487.921992.5
5171206.787.621791.7

The height between air cooler and SG is 14.5 m, the height of chimney is 10.5, the water in SG is 5.1 m, the pressure is 6.4 MPa, and the temperature at the inlet is 20°C.