Research Article

Design of the VISTA-ITL Test Facility for an Integral Type Reactor of SMART and a Post-Test Simulation of a SBLOCA Test

Table 5

Comparison of the major parameters under a steady-state condition.

ParameterSMART (design value)VISTA-ITL (ideal value)VISTA-ITL (test data)VISTA-ITL (MARS)

Power MWt 330.00.4320.45040.4504
PZR pres. MPa 15.0 15.0 14.9814.98
1st flow rate kg/s 2090.0 2.652.6132.6216
SG 1st inlet . K 596.15596.15596.75598.96
SG 1st outlet . K 568.85568.85568.85571.62
FW flow rate kg/s 160.80.2040.1520.153
FW temp. K 473.15473.15326.45325.15
SG 2nd inlet ā€‰ MPa 6.06.05.955.98
SG 2nd outlet ā€‰ MPa 5.25.25.195.22