Containment Depressurization Capabilities of Filtered Venting System in 1000 MWe PWR with Large Dry Containment

Korea Hydro and Nuclear Power, Central Research Institute, 70 Gil, Yuseong-Daero 1312, Yuseong-Gu, Daejeon 305-343, Republic of Korea

Received 24 February 2014; Revised 26 May 2014; Accepted 29 May 2014; Published 22 June 2014

Academic Editor: Inn Seock Kim

Copyright © 2014 Sang-Won Lee et al. This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.


After the Fukushima Daiichi nuclear power plant accident, the Korean government and nuclear industries performed comprehensive safety inspections on all domestic nuclear power plants against beyond design bases events. As a result, a total of 50 recommendations were defined as safety improvement action items. One of them is installation of a containment filtered venting system (CFVS) or portable backup containment spray system. In this paper, the applicability of CFVS is examined for OPR1000, a 1000 MWe PWR with large dry containment in Korea. Thermohydraulic analysis results show that a filtered discharge flow rate of 15 [kg/s] at 0.9 [MPa] is sufficient to depressurize the containment against representative containment overpressurization scenarios. Radiological release to the environment is reduced to considering the decontamination factor. Also, this cyclic venting strategy reduces noble gas release by 50% for 7 days. The probability of maintaining the containment integrity in level 2 probabilistic safety assessment (PSA) initiating events is improved twofold, from 43% to 87%. So, the CFVS can further improve the containment integrity in severe accident conditions.