Research Article

Containment Depressurization Capabilities of Filtered Venting System in 1000 MWe PWR with Large Dry Containment

Table 6

Level 2 PSA internal event affected by CFVS.

RCSFAIL MELTSTOPALPHACR-EJECTCF-EARLYCS-LATEEXVCOOLCF-LATESeq

No RCS failureRV ruptureNo alphaHighNo early CFFailureCooledLeak10
No RCS failureRV ruptureNo alphaHighNo early CFFailureCooledRupture11
No RCS failureRV ruptureNo alphaHighNo early CFFailureNot cooledLeak14
No RCS failureRV ruptureNo alphaHighNo early CFFailureNot cooledRupture15
No RCS failureRV ruptureNo alphaMediumNo early CFFailureCooledLeak32
No RCS failureRV ruptureNo alphaMediumNo early CFFailureCooledRupture33
No RCS failureRV ruptureNo alphaMediumNo early CFFailureNot cooledLeak36
No RCS failureRV ruptureNo alphaMediumNo early CFFailureNot cooledRupture37
No RCS failureRV ruptureNo alphaLowNo early CFNo failureNot cooledRupture52
No RCS failureRV ruptureNo alphaLowNo early CFFailureCooledLeak54
No RCS failureRV ruptureNo alphaLowNo early CFFailureCooledRupture55
No RCS failureRV ruptureNo alphaLowNo early CFFailureNot cooledLeak58
No RCS failureRV ruptureNo alphaLowNo early CFFailureNot cooledRupture59
No RCS failureCTMNT fail60
Hot leg breakRV ruptureNo alphaLowNo early CFNo failureNot cooledLeak76
Hot leg breakRV ruptureNo alphaLowNo early CFNo failureNot cooledRupture77
Hot leg breakRV ruptureNo alphaLowNo early CFFailureCooledLeak79
Hot leg breakRV ruptureNo alphaLowNo early CFFailureCooledRupture80
Hot leg breakRV ruptureNo alphaLowNo early CFFailureNot cooledLeak83
Hot leg breakRV ruptureNo alphaLowNo early CFFailureNot cooledRupture84
Hot leg breakCTMNT fail94