Research Article

Extended Station Blackout Coping Capabilities of APR1400

Table 2

Initial and boundary conditions.

ParameterValue

Reactor power (MWth)3983
Primary/secondary pressure (MPa)15.5/6.89
Hot leg/cold leg temperature (K)597.0/563.7
RCP seal flow rate (liter/s)1.325
RCS mass flow rate (kg/s)20,991
Steam mass flow rate/SG (kg/s)1130.2
SIT set pressure (MPa)4.025
POSRV capacity (kg/s)68.0 at 17.0 MPa
ADV capacity (kg/s)138.6 at 6.9 MPa
External injection pump shutoff pressure (MPa)1.5
Secondary injection flow rate (liter/s)14.7 at 0.1 MPa
Primary injection flow rate (liter/s)49.3 at 0.1 MPa