Research Article
Extended Station Blackout Coping Capabilities of APR1400
Table 2
Initial and boundary conditions.
| Parameter | Value |
| Reactor power (MWth) | 3983 | Primary/secondary pressure (MPa) | 15.5/6.89 | Hot leg/cold leg temperature (K) | 597.0/563.7 | RCP seal flow rate (liter/s) | 1.325 | RCS mass flow rate (kg/s) | 20,991 | Steam mass flow rate/SG (kg/s) | 1130.2 | SIT set pressure (MPa) | 4.025 | POSRV capacity (kg/s) | 68.0 at 17.0 MPa | ADV capacity (kg/s) | 138.6 at 6.9 MPa | External injection pump shutoff pressure (MPa) | 1.5 | Secondary injection flow rate (liter/s) | 14.7 at 0.1 MPa | Primary injection flow rate (liter/s) | 49.3 at 0.1 MPa |
|
|