Input Calibration and Validation of RELAP5 Against CIRCUS-IV Single Channel Tests on Natural Circulation Two-Phase Flow Instability
Table 5
Difference between calculated and experimental values, test I-1.
| Parameters | Calib. input | Varied input parameters | | | Tin −1°C | Tin +1°C | HL R 0 kW | HL R 0.4 kW | Kin −25% | Kin +25% |
| Oscillation period (%) | 27.13 | 39.75 | 9.21 | −3.84 | 50.76 | 27.74 | 25.30 |
| Flow rate (%) | Average | 7.07 | −1.16 | 10.03 | 3.27 | −2.07 | 7.73 | 5.04 | Maximum | −4.27 | −16.91 | 14.62 | 28.78 | −40.38 | −4.47 | −0.09 | Minimum | 31.65 | 28.41 | 47.90 | 30.72 | 35.73 | 32.57 | 31.67 |
| Inlet riser temperature (°C) | Average | −1.23 | −1.40 | −0.75 | −1.00 | −0.82 | −1.29 | −1.15 | Maximum | −1.00 | −1.01 | −0.94 | −0.87 | −0.98 | −1.07 | −0.95 | Minimum | −0.37 | −0.96 | 0.13 | −0.95 | 0.91 | −0.44 | −0.46 |
| Middle tiser temperature (°C) | Average | −0.23 | −0.55 | 0.27 | −0.30 | 0.24 | −0.31 | −0.21 | Maximum | 0.05 | 0.00 | 0.18 | 0.38 | −0.24 | 0.02 | 0.07 | Minimum | −0.38 | −0.99 | 0.17 | −0.24 | 0.29 | −0.49 | −0.41 |
| Outlet riser temperature (°C) | Average | −1.21 | −1.61 | −0.56 | −0.62 | −0.98 | −1.30 | −1.17 | Maximum | 0.31 | 0.35 | 0.29 | 0.22 | 0.29 | 0.30 | 0.28 | Minimum | −1.21 | −1.85 | −0.59 | −0.48 | −1.25 | −1.33 | −1.21 |
| Inlet pressure (mbar) | Average | 2.52 | 3.77 | 2.74 | 2.47 | 4.06 | 2.60 | 1.45 | Maximum | 3.53 | 3.92 | 7.88 | 6.14 | 3.76 | 6.23 | 4.58 | Minimum | 29.07 | 37.11 | 13.71 | 0.69 | 49.49 | 33.78 | 18.78 |
|
|
The values in bold are maximum and minimum values obtained in simulations.
|