Research Article

Comparative Neutronics Analysis of DIMPLE S06 Criticality Benchmark with Contemporary Reactor Core Analysis Computer Code Systems

Table 9

The assembly power distribution by a direct and two-step modeling for DIMPLE S06A.

Analysis codeNormalized assembly powerRMS (%)
CenterEdge

MCNP direct0.6280.372
SERPENT direct (ref.)0.6270.373(0.11)(1)
CASMO direct (ref.)0.6160.384(1.15)
NEWT direct (ref.)0.6270.373(0.10)

No ADF
 SERPENT/PARCS(2)−0.290.490.18 (0.07)
 CASMO/PARCS0.28−0.450.17 (1.33)
 NEWT/PARCS−0.010.010.00 (0.10)

ADF
 SERPENT/PARCS−0.140.240.09 (0.02)
 CASMO/PARCS−0.600.960.37 (0.79)
 NEWT/PARCS−0.831.390.52 (0.41)

( ): RMS error for MCNP and two-step.
(2)Relative difference (%): (direct − two-step)/direct 100.