Research Article
Comparative Neutronics Analysis of DIMPLE S06 Criticality Benchmark with Contemporary Reactor Core Analysis Computer Code Systems
Table 9
The assembly power distribution by a direct and two-step modeling for DIMPLE S06A.
| Analysis code | Normalized assembly power | RMS (%) | Center | Edge |
| MCNP direct | 0.628 | 0.372 | | SERPENT direct (ref.) | 0.627 | 0.373 | (0.11)(1) | CASMO direct (ref.) | 0.616 | 0.384 | (1.15) | NEWT direct (ref.) | 0.627 | 0.373 | (0.10) |
| No ADF | | | | SERPENT/PARCS(2) | −0.29 | 0.49 | 0.18 (0.07) | CASMO/PARCS | 0.28 | −0.45 | 0.17 (1.33) | NEWT/PARCS | −0.01 | 0.01 | 0.00 (0.10) |
| ADF | | | | SERPENT/PARCS | −0.14 | 0.24 | 0.09 (0.02) | CASMO/PARCS | −0.60 | 0.96 | 0.37 (0.79) | NEWT/PARCS | −0.83 | 1.39 | 0.52 (0.41) |
|
|
( ): RMS error for MCNP and two-step. (2)Relative difference (%): (direct − two-step)/direct 100.
|