Research Article
HTR-Based Power Plants’ Performance Analysis Applied on Conventional Combined Cycles
Table 4
Losses due to internal irreversibilities assumed for the case studies.
| | CBC-reg/He | RC-CO2 | He/NH3 (no reg) | He/CO2 | He/C2H6 (no reh) | He/H2O (no reg) | He/Xe (no reg) |
| in HTR (%) | 3 | 3 | 3 | 3 | 3 | 3 | 3 | in HE (%) | 2 | 2 | 2 | 2 | 2 | 2 | 3 | in HRE (%) | | | 2 | 2 | 2 | 2 | 3 | regenerator (%) | 2 | 2 | | 2 | 2 | | | IHE (%) | 97 | 92 | 92 | 92 | 92 | 92 | 92 | HR (%) | | | 92 | 92 | 92 | 92 | 92 | regenerator (%) | 92 | 92 | | 90 | 92 | | | HTR-IHE (K) | 50 | 80 | 50 | 50 | 50 | 50 | 50 | Reg () (K) | 20 | 20 | | 20 | 20 | | | in BC/RC (K) | | — | 40 | 40 | 40 | 40 | 40 | Iη BC turbine (%) | 94 | | 94 | 94 | 94 | 94 | 94 | Iη BC compressor (%) | 88 | | 88 | 88 | 88 | 88 | 88 | Iη RC pump (%) | | 90 | 90 | 90 | 90 | 90 | 90 | Iη RC turbine (%) | | 92 | 92 | 92 | 92 | 92 | 92 |
|
|