Research Article

HTR-Based Power Plants’ Performance Analysis Applied on Conventional Combined Cycles

Table 7

The CC state points for the CBC with helium as WF and carbon dioxide, xenon, ethane, ammonia and water as WF for the RC.

Point

He-CO2
(K)290691.81173575.2295335.9535.2510535.2384.4355.9352.1
(kPa)100733.3718.61025982416164000031140305296102598240800
(m3/kg)602319633911711.3281.1252.4582.8393.12110.349.2491.203

He-Xe (no regeneration)
(K)290632.21173620282363.8580495.4580333.9
(kPa)100593581.11024985408004000024480240004985
(m3/kg)60232214419212630.5880.4990.9291.1211.4573.347

He-C2H6 (no reheating)
(K)290706.91173565295342.5525382.8362.5385.3
(kPa)100771.8756.4102391841616400003997391840800
(m3/kg)602319023221115103.0212.373.84122.7721.222.473

He-NH3 (no regeneration)
(K)290597.51173650295305.9570472570318.6
(kPa)100519.2508.9102909.641208400001581015500909.6
(m3/kg)602323904788132401.6461.6015.0159.58715.42157.7

He-H2O (no regeneration)
(K)290459.71173810295296.6770598.2770295
(kPa)100282.3276.71022.621350123432510751105402.621
(m3/kg)602333818805164901.0020.9877.02817.6430.7741380