Table of Contents Author Guidelines Submit a Manuscript
Science and Technology of Nuclear Installations
Volume 2015 (2015), Article ID 840507, 8 pages
http://dx.doi.org/10.1155/2015/840507
Research Article

AP1000 Shield Building Dynamic Response for Different Water Levels of PCCWST Subjected to Seismic Loading considering FSI

Beijing Key Laboratory of Passive Nuclear Safety Technology, North China Electric Power University, Beijing 102206, China

Received 8 October 2014; Accepted 12 January 2015

Academic Editor: Alejandro Clausse

Copyright © 2015 Daogang Lu et al. This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

Linked References

  1. C. Zhao, J. Chen, and Q. Xu, “Dynamic analysis of AP1000 shield building for various elevations and shapes of air intakes considering FSI effects subjected to seismic loading,” Progress in Nuclear Energy, vol. 74, pp. 44–52, 2014. View at Publisher · View at Google Scholar · View at Scopus
  2. M. Jolie, M. M. Hassan, and A. A. El Damatty, “Assessment of current design procedures for conical tanks under seismic loading,” Canadian Journal of Civil Engineering, vol. 40, no. 12, pp. 1151–1163, 2013. View at Publisher · View at Google Scholar · View at Scopus
  3. R. Livaoğlu and A. Doğangün, “Simplified seismic analysis procedures for elevated tanks considering fluid-structure-soil interaction,” Journal of Fluids and Structures, vol. 22, no. 3, pp. 421–439, 2006. View at Publisher · View at Google Scholar · View at Scopus
  4. M. Moslemi, M. R. Kianoush, and W. Pogorzelski, “Seismic response of liquid-filled elevated tanks,” Engineering Structures, vol. 33, no. 6, pp. 2074–2084, 2011. View at Publisher · View at Google Scholar · View at Scopus
  5. M. Masoudi, S. Eshghi, and M. Ghafory-Ashtiany, “Evaluation of response modification factor (R) of elevated concrete tanks,” Engineering Structures, vol. 39, pp. 199–209, 2012. View at Publisher · View at Google Scholar · View at Scopus
  6. D.-S. Lee, M.-L. Liu, T.-C. Hung, C.-H. Tsai, and Y.-T. Chen, “Optimal structural analysis with associated passive heat removal for AP1000 shield building,” Applied Thermal Engineering, vol. 50, no. 1, pp. 207–216, 2013. View at Publisher · View at Google Scholar · View at Scopus
  7. Y. Choi, S. Lim, B.-H. Ko et al., “Dynamic characteristics identification of reactor internals in SMART considering fluid-structure interaction,” Nuclear Engineering and Design, vol. 255, pp. 202–211, 2013. View at Publisher · View at Google Scholar · View at Scopus
  8. Westinghouse, The AP1000 European DCD, UK AP1000 Safety, Security, and Environmental Report, p. 51–53.
  9. N. Hosseinzadeh, H. Kazem, M. Ghahremannejad, E. Ahmadi, and N. Kazem, “Comparison of API650-2008 provisions with FEM analyses for seismic assessment of existing steel oil storage tanks,” Journal of Loss Prevention in the Process Industries, vol. 26, no. 4, pp. 666–675, 2013. View at Publisher · View at Google Scholar · View at Scopus
  10. H. Sezen, R. Livaoglu, and A. Dogangun, “Dynamic analysis and seismic performance evaluation of above-ground liquid-containing tanks,” Engineering Structures, vol. 30, no. 3, pp. 794–803, 2008. View at Publisher · View at Google Scholar · View at Scopus