Research Article
Probabilistic Dynamics for Integrated Analysis of Accident Sequences considering Uncertain Events
Table 4
Uncertain conditions and parameters.
| Number | Full parameter name | Reference | Distribution | Min. | Max. |
| 1 | Number of moles of steam | | Uniform | 1383240 | 2034004 | 2 | Temperature inside the containment | 382.05 | Uniform | 369.75 | 383.55 | 3 | Pressure inside the containment | 2.28 | Uniform | 2 | 2.5 | 4 | Factor of spray efficiency to condensate hydrogen | 1 | Uniform | 0.5 | 1.5 | 5 | Factor of hydrogen mass flow rate in the range 1: 5875; 7000 or 9401; 14220 | 0.5 | Uniform | 0 | 1 | 6 | Factor of hydrogen mass flow rate in the range 2: 7001; 9400 | 0.5 | Uniform | 0 | 1 | 7 | Factor of water injection (SIS) availability | 0.5 | Uniform | 0 | 1 | 8 | Factor of spray injection (CHRS) availability | 0.5 | Uniform | 0 | 1 | 9 | Coefficient of recombined hydrogen flow rate | 0.003 | Uniform | 0.0015 | 0.0045 | 10 | Coefficient of recombined hydrogen flow rate | 0.0037 | Uniform | 0.00185 | 0.00555 | 11 | Factor of peak pressure to cause a rupture | 0.5 | Uniform | 0 | 1 | 12 | Activation of spray at 2.4 MPa pressure limit | 0 | Bernoulli (0.5) | 0 | 1 |
|
|