Research Article
A Calculation Method for the Sloshing Impact Pressure Imposed on the Roof of a Passive Water Storage Tank of AP1000
Table 4
Total impact force from measuring data.
| Case no. | Filling depth [mm] | Amplitude [mm] | Impact force [N] |
| 1 | 217 mm | 12 | 11.31001 | 24 | 60.37129 | 36 | 91.28681 |
| 2 | 177 mm | 12 | 4.370317 | 24 | 25.62775 | 36 | 41.8155 |
| 3 | 197 mm | 12 | 7.423492 | 24 | 36.49382 | 36 | 56.19478 |
| 4 | 237 mm | 12 | 23.1682 | 24 | 84.23761 | 36 | 117.9033 |
|
|