Research Article
A Calculation Method for the Sloshing Impact Pressure Imposed on the Roof of a Passive Water Storage Tank of AP1000
Table 5
The comparison between calculated pressure and measured pressure.
| Case no. | Amplitude [mm] | Measured pressure (MIP) [Pa] | Calculated pressure (CIP) [Pa] | Error (%) |
| 1 | 12 | 500.62 | 354.6718 | −29.1536 | 24 | 1549.30 | 1806.679 | 16.6126 | 36 | 2074.05 | 2678.605 | 29.14851 |
| 2 | 12 | 263.27 | 0 | −100 | 24 | 913.30 | 793.3394 | −13.1349 | 36 | 1243.44 | 1316.61 | 5.884514 |
| 3 | 12 | 397.514 | 40.209 | −89.8856 | 24 | 1221.34 | 1248.657 | 2.236658 | 36 | 1579.48 | 1887.5 | 19.50133 |
| 4 | 12 | 757.21 | 743.9886 | −1.74607 | 24 | 1753.86 | 2363.192 | 34.74232 | 36 | 2445.99 | 3253.825 | 33.02691 |
|
|