Abstract

Generally the piping system of a nuclear power plant (NPP) has to be designed for normal loads such as dead weight, internal pressure, temperature, and accidental loads such as earthquake. In the proposed paper, effect of Stockbridge damper to mitigate the response of piping system of NPP subjected to earthquake is studied. Finite element analysis of piping system with and without Stockbridge damper using commercial software SAP2000 is performed. Vertical and horizontal components of earthquakes such as El Centro, California, and Northridge are used in the piping analysis. A sine sweep wave is also used to investigate the control effects on the piping system under wide frequency range. It is found that the proposed Stockbridge damper can reduce the seismic response of piping system subjected to earthquake loading.

1. Introduction

Usually nuclear power plant (NPP) piping system needs to be designed for various loads such as dead weight, internal pressure, temperature, and accidental loads as well as for seismic loads. These loads can occur inside the nuclear power plant piping system and affect the operation of the plant. Researchers have investigated ways to reduce pipe vibration using various devices, including snubbers, pipe hangers, support systems, and isolators. Kunieda et al. [1] proposed three control devices for piping systems to increase the damping ratio: a direct damper, vibration absorber, and connecting damper. Olson and Tang [2] proposed snubber and seismic stops to suppress the vibration of a nuclear power plant piping system; however, it is very difficult to frequently inspect snubbers in the high-radiation conditions in a nuclear power plant, and the cost for installation was prohibitively expensive. Shimuzu et al. [3] developed a seismic response analysis procedure of the piping system and performed an evaluation of the piping response by comparing simulated results and tested results. Park et al. [4] performed the shaking table test and simulation for the main steam and feedwater lines with conventional snubbers and energy absorbing supports. Parulekar et al. [5] performed analytical and experimental research to reduce the vibration of the piping and equipment of a nuclear power plant using elastoplastic dampers (EPD). Abe et al. [6] conducted the seismic proving test of Lead Extrusion Damper (LED) and developed the characteristic evaluation formula for LED. Moreover, Fujita et al. [7] proposed a method of nonlinear seismic response analysis for a piping system using a combination of the Finite Element Method (FEM) and the Differential Algebraic Equations (DAE). Bakre et al. [8] inspected the effectiveness of sliding friction dampers for piping systems using analytical and experimental methods. Bakre et al. [9] attempted to optimize x-plate dampers and the seismic effectiveness of these dampers for a piping system in industrial installations.

In this study, a Stockbridge damper (SBD), originally developed by Stockbridge in 1925 [10], is suggested to suppress the vibration of a nuclear power plant piping system under earthquakes. Wagner et al. [11] established a theoretical analysis of the response characteristics of SBD to verify a theoretical predictions experimental test. The SBD was used to reduce the vibration of slender structures in wind, such as overhead transmission lines and stayed cables [1215]. Vecchiarelli et al. [12] performed numerical analysis to predict the vertical, steady-state, aeolian vibration of a single conductor span attached with a Stockbridge-type damper. Thereafter, Barry [13] developed a finite element model to evaluate the vibrational response of a single conductor with a Stockbridge damper and investigate the effects of the Stockbridge damper. Urushadze et al. [14] conducted experimental and numerical verification of wind-induced vibration of hangers on the pedestrian bridge and suggested to equip the hangers with Stockbridge dampers. To investigate the linear and nonlinear dynamic behavior of asymmetric Stockbridge damper, an experimental test and a numerical analysis were performed by N. Barbieri and R. Barbieri [15].

In this study, a piping system (ASCE CLASS1 SA312 GRADE TP316 SCH) was installed in identical conditions to those in a real nuclear power plant and was used to investigate the control performance of the SBD. Finite element analysis of piping system with and without Stockbridge damper was performed using commercial software SAP2000. A sine sweep wave was used to investigate the control effects on the piping system under wide frequency range. In order to confirm the control effects of the Stockbridge damper under random earthquake vibration, the three selective (El Centro, California, and Northridge) earthquakes were used in this investigation.

2. Piping System

2.1. Outline of Piping System

The nuclear power plant piping system was composed of 2- and 3-inch sized pipes; the length of the axis of ordinates is 17.8 m; the end of the pipe tip was fixed; and 2 reducers were modeled as hinge conditions. It is assumed that the inner space of the pipe was filled with water. The water was modeled as an additional mass.

Figure 1 shows the piping system modeled by SAP2000. The material properties and cross-sectional properties of the pipe are shown in Tables 1 and 2. All properties were applied as the values suggested by the design criteria.

2.2. Free Vibration Analysis

A free vibration analysis was performed with respect to the piping system in order to calculate the parameters of the damper such as mass, frequency ratio, and damping ratio. From the free vibration analysis, the first to third modes show very complex modal shapes which are a combination of horizontal and vertical shapes as shown in Figures 24. The first and third mode shapes are predominantly horizontal mode shaped, and the second mode shape is predominantly vertical mode shaped. The maximum amplitudes of where the damping device will be installed were marked using a red color dot. The dynamic properties of the piping system calculated from free vibration analysis results are shown in Table 3.

Since the main control target modes are the first to third modes, each generalized mass was calculated up to the third mode.

3. Design of Dampers

We utilized a two-step process to design a damper to reduce the vibration of the piping system. The first step is the calculation of the mass ratio, frequency ratio, and damping ratio of the damper. Then, in the second step, the specific design of the SBD is done. The design parameters of the damper are determined from the eigenvalue analysis results. According to Den Hartog’s formula, the mass ratio, optimum frequency ratio, and optimum damping ratio are calculated as follows [16]:where is the effective damping ratio of the piping system, is the mass ratio, is the optimum frequency ratio, and is the optimum damping ratio of the damper.

3.1. Stockbridge Damper

The SBD is composed of a mass part and messenger cable parts, as shown in the SBD cross section in Figure 5. The messenger cable is comprised of several steel wire strands and can dissipate the energy of the vibration through strand friction. In this paper, both sides of the SBD play a different role. The left part of the SBD reduces the -direction vibration of the piping system, while the right part of the SBD suppresses the -direction vibration of the piping system.

The equation of motion for SBD is given aswhere is the mass matrix, is the damping matrix, and is the stiffness matrix; and , , and are the acceleration, velocity, and displacement of the SBD, respectively.

Undamped natural frequencies of the SBD system are obtained by [11]where is the frequency of the SBD, is the mass, is the radius of gyration of mass, is the distance between the attachment point and the center of gravity of the mass, and is the bending stiffness of messenger cable (where ). The basic design for the SBD was calculated using the above equations, and the target frequency was then adjusted by fine tuning. The properties of the SBD are shown in Table 4.

4. Base Excitation

4.1. Sine Sweep Wave

In order to investigate the frequency ranges of the piping system, a sine sweeping wave with peak acceleration of 1.0 m/sec2 varying from 0.1 Hz to 20 Hz was applied to the nuclear power plant piping system with and without the SBD for - and -directions (Figure 6).

4.2. Earthquake Ground Motion

In this study, recorded earthquakes were used to verify that the proposed SBD can reduce the vibration response of the nuclear power plant piping system. El Centro, California, and Northridge earthquakes were selected for dynamic analysis. El Centro earthquakes of the -, -, and -axis direction were used to check the horizontal and vertical behavior of the piping system. The earthquake time history has a 50-second duration and 0.02-second time steps. Peak ground accelerations were scaled to 0.34 g, 0.21 g, and 0.21 g for the -, -, and -axis directions, respectively. The time history acceleration and response spectrum of the ground motion in each direction were shown in Figure 7. While the horizontal earthquakes have an energy distribution between 1 Hz and 5 Hz, vertical earthquakes have more vibration energy in 10 Hz.

Vertical earthquakes were scaled to fit 1/2 of PGA of the horizontal ground motion for California and Northridge earthquakes. Therefore, the PGAs of California and Northridge earthquakes were scaled from 0.15 g to 0.075 g and from 0.34 g to 0.17 g in the vertical direction, respectively. The ground motion of each direction and response spectrum are shown in Figures 8 and 9.

5. Results and Discussion

5.1. Response of Piping System Subjected to Sine Sweep Excitation

The accelerations of the piping system were measured in the maximum amplitude when the SBD was not installed on the piping system (red spot in Figures 24). Figure 10 shows the time history response and response spectrum of the -directional response after inputting the signal in the -direction. This shows that the first mode (1.9 Hz) is dominant. However, in the case of Figure 11, the -direction response of the piping system after applying the -directional wave is shown. This simultaneously shows the peak in the first mode shape at 1.9 Hz (-directional mode) and the second mode shape at 2.3 Hz (-directional mode) of the piping system under the sine sweep wave because the modal shape of the piping system was mixed. Figure 13 also shows the same trend with inverse load conditions from those in Figure 11. Figure 12 shows the same trend with Figure 10. From the results of the sine sweep wave, it is confirmed that the proposed SBD can reduce the vibration in all frequency domains (0.1 Hz to 20 Hz). Based on the given results, it is evident that having a wide frequency range is one advantage of the SBD.

5.2. Response of Piping System Subjected to Earthquakes

An earthquake analysis was performed to investigate the applicability with respect to the piping system and to confirm the vibration mitigation of the piping system with and without the SBD under the recorded earthquakes. The accelerations of the piping system were measured for the maximum amplitude when the SBD was not installed on the piping system (red spot in Figures 24). Figure 14 shows the time history response and frequency domain response of the piping system with and without the SBD in the -, -, and -axis directions when El Centro earthquake was applied to the system.

The -directional vibration of the piping system appeared to be almost invisible when the SBD was installed (Figure 14(a)). The maximum acceleration decreased from 1.58 m/s2 to 0.02 m/s2, and the root mean square (RMS) was reduced from 0.13 m/s2 to 0.002 m/s2 in the -direction. Each decreasing ratio was 99.0% and 98.5%, respectively. In the case of the -direction response, the maximum acceleration decreased from 6.52 m/s2 to 1.97 m/s2, and RMS was reduced from 1.24 m/s2 to 0.29 m/s2 when the SBD was applied. Table 5 shows the maximum acceleration, RMS response, and its decreasing ratio where the SBD was installed. In this paper, the maximum acceleration and RMS were used to evaluate the vibration of the piping system. The RMS are calculated as follows: where is the length of data and is the acceleration of th time step. The RMS represents the amplitude related with an energy amount, which indicates the destructive ability of the vibration.

The -directional El Centro earthquake shows a large amount of energy on the adjacent 10 Hz, unlike earthquakes of the other directions (Figure 7(a)). Although the proposed SBD was not designed with respect to that frequency area, nevertheless the control effects of the damper can be confirmed based on the peak acceleration and response spectrum. Since the SBD was not designed for -directional response, the control system has some effects on the responses of -directions. This phenomenon can be explained by the reason of the piping system having complex modal shapes and coupled responses. In other words, if -direction and -direction responses of the piping system can occur by earthquake in -direction, then it is obvious that the SBD can be capable of suppressing the vibration in -direction with the other both directions instead of not being designed for -direction.

Figures 15 and 16 show the time history response and frequency domain response of the nuclear power plant piping system with and without the SBD in the - and -axis directions under California and Northridge earthquakes. The acceleration response of both earthquakes was considerably suppressed by the proposed SBD. With respect to California earthquake, the maximum acceleration of the piping system decreased from 3.22 m/s2 to 1.17 m/s2, and RMS response was reduced from 0.67 m/s2 to 0.19 m/s2 in the -direction. Each decreasing ratio was 63.8% and 71.6%, respectively. In the case of the -direction, the decreasing ratio of the maximum acceleration and RMS response decreased by 74.3% and 73.4%, respectively.

This demonstrates the good control performance of the SBD for Northridge earthquake, as shown in Figure 16. The maximum acceleration and RMS response decreased by 60.2% and 74.0% in the -direction, respectively, and 58.5% and 71.9% in the -direction, respectively. The maximum acceleration and RMS response for each earthquake are shown in Tables 6 and 7.

Figure 17 shows the response of the piping system in the -direction under the -directional El Centro earthquake and the response of the piping system in the -direction under the -directional El Centro earthquake. It can be seen that the response reduction of the piping system in Figure 17 is more noticeable than the trend shown in Figures 1416. While the control effects of the SBD in Figures 1416 show extremely effective behavior at tuned frequencies (first and second mode), the frequency response of Figure 17 is 2 Hz, which shows a wide range of frequency response. The response decreasing ratio of the piping system was large when the load direction and response direction were different. This is because the SBD in this paper was actually designed for first and second frequency modes; therefore, the SBD extremely suppressed the vibration of the piping system. However, that the SBD can also reduce vibrations beyond the design frequency range was already confirmed in our previous results. The results of California earthquake also show a similar trend with those of El Centro earthquake (Figure 18). The directional results for both earthquakes are summarized in Tables 8 and 9. The reduction ratio of all responses is more than 90%.

6. Conclusion

From the study performed, SBD is recommended to control the seismic response of NPP piping system. Effect of SBD to control the seismic response of piping system is demonstrated considering El Centro, California, and Northridge earthquake excitations. The piping system (ASCE CLASS1 SA312 GRADE TP316 SCH) was modeled under the same conditions as in an actual nuclear power plant. The SBD was designed for low order frequency modes using free vibration analysis results. The controlled responses of the time and frequency domain were compared with uncontrolled responses of the piping system under horizontal and vertical earthquakes. It was confirmed through sine sweep wave analysis that the proposed damper can reduce wide frequency vibration responses.

In the earthquake results, the maximum acceleration declined by about 99%, 69%, and 11% in each direction under El Centro earthquake, respectively. The maximum accelerations decreased by 63% in -direction and 74% in -direction under California earthquake. In the case of the Northridge earthquake, reductions of each acceleration were found to be 60% and 58% in -direction and -direction, successively.

From the earthquake response analysis results, it was found that the proposed SBD can reduce not only the targeted vibration modes of the piping system but also other modes under earthquakes. Most importantly, it was also confirmed that the proposed SBD can effectively reduce the vibration of a nuclear power plant piping system under earthquakes.

Competing Interests

The authors declare that they have no competing interests.

Acknowledgments

This work was supported by the National Research Foundation of Korea Grant funded by the Korean Government (NRF-2014R1A2A1A10049538) and the Nuclear Power Core Technology Development Program of the Korea Institute of Energy Technology Evaluation and Planning (KETEP) grant financial resource from the Ministry of Trade, Industry & Energy, Republic of Korea (no. 20131520400080).