The comparison of the local burnup (unit in MWd/kgU) at three levels given by the present formula (AN) and MC calculations.


1/4 5.96 5.94 21.48 21.33 36.57 36.30
5/8 6.11 6.09 22.11 22.09 37.69 37.80
13/16 6.29 6.29 23.05 23.11 39.53 39.75
29/32 6.48 6.49 24.40 24.22 42.42 41.83
61/64 6.72 6.74 26.62 26.37 47.48 46.55
125/128 7.06 7.08 30.13 30.38 55.50 55.91
127/128 7.68 7.72 37.20 37.31 71.75 71.64
Average errors 0.32% 0.55% 0.84%