Research Article

Sizing of the Vacuum Vessel Pressure Suppression System of a Fusion Reactor Based on a Water-Cooled Blanket, for the Purpose of the Preconceptual Design

Table 2

Minimum ST volume in m3.

PHTS vol.300 m3600 m31000 m3

ST liq. 0.50.60.70.80.50.60.70.80.50.60.70.8

ST tempHeat source

293.155 MW110792479369521421788153413433521293925222208
10 MW1201100386075322361866160114023615301725892267
15 MW1295108192781223291944166814613709309526562326
20 MW1389115999587124232022173515203802317427232385

303.155 MW1246104089278224092011172615123961330628372485
10 MW1351112896884825152099180215784066339429132551
15 MW14571216104491426202187187716444172348229892617
20 MW15621304111998027262275195317104277357030642684

313.155 MW14231189102089427532299197317284526377932442841
10 MW15441289110796928742399206018044646388033302917
15 MW166513901193104529942500214618804767398034172993
20 MW178514901279112131152601223219554887408135033068