Science and Technology of Nuclear Installations / 2016 / Article / Tab 2 / Research Article
Sizing of the Vacuum Vessel Pressure Suppression System of a Fusion Reactor Based on a Water-Cooled Blanket, for the Purpose of the Preconceptual Design Table 2 Minimum ST volume in m3 .
PHTS vol. 300 m3 600 m3 1000 m3 ST liq. 0.5 0.6 0.7 0.8 0.5 0.6 0.7 0.8 0.5 0.6 0.7 0.8 ST temp Heat source 293.15 5 MW 1107 924 793 695 2142 1788 1534 1343 3521 2939 2522 2208 10 MW 1201 1003 860 753 2236 1866 1601 1402 3615 3017 2589 2267 15 MW 1295 1081 927 812 2329 1944 1668 1461 3709 3095 2656 2326 20 MW 1389 1159 995 871 2423 2022 1735 1520 3802 3174 2723 2385 303.15 5 MW 1246 1040 892 782 2409 2011 1726 1512 3961 3306 2837 2485 10 MW 1351 1128 968 848 2515 2099 1802 1578 4066 3394 2913 2551 15 MW 1457 1216 1044 914 2620 2187 1877 1644 4172 3482 2989 2617 20 MW 1562 1304 1119 980 2726 2275 1953 1710 4277 3570 3064 2684 313.15 5 MW 1423 1189 1020 894 2753 2299 1973 1728 4526 3779 3244 2841 10 MW 1544 1289 1107 969 2874 2399 2060 1804 4646 3880 3330 2917 15 MW 1665 1390 1193 1045 2994 2500 2146 1880 4767 3980 3417 2993 20 MW 1785 1490 1279 1121 3115 2601 2232 1955 4887 4081 3503 3068