Research Article

Multiscale Thermal Hydraulic Study under the Inadvertent Safety Injection System Operation Scenario of Typical Pressurized Water Reactor

Table 2

Steady calculation results and comparison with design value.

ParametersRELAP5 valueDesign valueError

Primary loop pressure (MPa)15.2615.20.39%
Reactor outlet temperature (°C)316.1315.50.19%
Reactor inlet temperature (°C)289.0288.50.17%
Primary flow rate (kg/s)3230.253227.8960.07%
SG mass flow rate (kg/s)283.62280.561.09%
SG pressure (MPa)5.5445.540.07%
Upper plenum flow rate (kg/s)31.6505732.27881.94%