Research Article

Analysis of NEA-NSC PWR Uncontrolled Control Rod Withdrawal at Zero Power Benchmark Cases with NODAL3 Code

Table 8

Effect of radial node number per FA for transient hot pellet results in Cases A, B, and D.

ParametersResultsReferenceNODAL3 (node number per FA)
1 × 12 × 24 × 4

Case A
Maximum fuel temperature at hot pellet centerline, °CD6631.8629.2 (0.41%)632.9 (0.17%)632.9 (0.17%)

Case B
Maximum fuel temperature at hot pellet centerline, °CD6478.2459.8 (3.85%)460.9 (3.62%)461.3 (3.53%)

Case D
Maximum fuel temperature at hot pellet centerline, °CD6451.4459.8 (1.86%)457.8 (1.42%)458.2 (1.51%)

Note. The axial node number is 1 × 18 nodes per axial layer; number in parentheses are the absolute value of relative deviation of NODAL3 with the reference.