Research Article
RELAP5 Simulation of PKL Facility Experiments under Midloop Conditions
Table 1
E3.1, F2.1, and F2.2 initial conditions.
| | PKL III E OECD-SETH | PKL III F OECD-PKL | PKL III F OECD-PKL | E3.1 | F2.1 Run 1 | F2.1 Run 2 | F2.2 Run 1 |
| Primary side | Power (kW) | 220 | 220 | 220 | 220 | Pressure (kPa) | 100 | 100 | 100 | 100 | Temperature pressurizer (°C) | 50 | 150–170 | 50 | 50 | Temperature at core outlet (°C) | 60 | 60 | 60 | 60 | Level (hot legs) | loop | loop | RCL lower edge | loop |
| Secondary side | | Two SGs filled with water and one of them operable (200 kPa) | Two SGs filled with water and one of them operable (200 kPa) | Two SGs filled with water and one of them operable (200 kPa) | One SG filled with water and operable (200 kPa) |
|
|